Renesas R5S72621 Manual Do Utilizador

Página de 2152
 
Section 16   Renesas Serial Peripheral Interface 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 787 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
Bit Bit 
Name 
Initial 
Value R/W Description 
TEND 1 
R Transmit 
End 
This bit is set to 1 when transmission is completed, 
and this bit is 0 when transmission is not completed.
[Clearing condition] 
  When transmit data are moved from the transmit 
register to the shift register. 
[Setting condition] 
  When the number of data units in the transmit 
buffer (SPTX) is zero when a serial transfer is 
completed. 
SPTEF 
Transmit Buffer Empty Flag 
Indicates that the number of transmit data units in the 
transmit buffer (SPTX) is equal to or less than the 
transmit buffer data triggering number specified in 
the buffer control register (SPBFCR). 
0: The number of transmit data units in the transmit 
buffer is equal to or greater than the specified 
transmit buffer data triggering number.  
1: The number of transmit data units in the transmit 
buffer is less than the specified transmit buffer 
data triggering number. 
[Clearing condition] 
  When data is written to the transmit buffer until 
the number of transmit data units in the transmit 
buffer exceeds the specified transmit buffer data 
triggering number. 
[Setting conditions] 
  When the number of transmit data units in the 
transmit buffer is less than the specified transmit 
buffer data triggering number. 
  When transmit buffer data reset is enabled. 
  Power-on reset 
4, 3 
 All 
Reserved 
The write value should always be 0. Otherwise, 
operation cannot be guaranteed.