3com 2200 Manual Do Utilizador

Página de 200
Administering FDDI Paths
8-7
Enter the path (
= primary, 
= secondary).
See the following example of path information:
Table 8-3 describes these statistics.
Setting
tvxLowerBound
The tvxLowerBound attribute specifies the minimum time value of fddiMAC 
TvxValue that will be used by any MAC that is configured onto this path. A 
MAC uses its valid transmission timer (TVX) to detect and recover from 
certain ring errors. If a valid frame has not passed through a MAC during the 
time indicated by fddiMACTvxValue, the MAC reinitializes the ring. 
By adjusting the tvxLowerBound value, you specify how quickly the ring 
recovers from an error. The lower you set this value, the faster the network 
reacts to problems, but the ring might be reinitialized when there is no 
problem. The higher you set this value, the less chance of frequent 
reinitializations, but the network will take longer to recover from errors.
 stn       path     ringLatency     traceStatus
   1    primary              16             0x0
   1  secondary              16             0x0
   1      local               0             0x0
 stn       path     tvxLowBound    tMaxLowBound         maxTReq
   1    primary         2500 us       165000 us       165000 us
   1  secondary         2500 us       165000 us       165000 us
   1      local         2500 us       165000 us       165000 us
Table 8-3   Description of Fields for FDDI Path Attributes 
Field
Description
maxTReq
Maximum time value of fddiMACT-Req that will be used by any 
MAC that is configured in this path. This value can be user-defined.
ringLatency
Total accumulated latency of the ring associated with this path
tmaxLowBound
Minimum time value of fddiMACT-Max that will be used by any 
MAC that is configured in this path. This value can be user-defined.
traceStatus
Current Trace status of the path
tvxLowBound
Minimum time value of fddiMACTvxValue that will be used by any 
MAC that is configured in this path. This value can be user-defined.