Cooper Lighting CFD Folheto
N o t e s : For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without
notice. Electronic ballast may cause interference with other electronic devices. If interference occurs, move the device away from the
product or plug/connect into a different circuit/outlet.
notice. Electronic ballast may cause interference with other electronic devices. If interference occurs, move the device away from the
product or plug/connect into a different circuit/outlet.
1
The KSH25 provides improved visual performance and wide angle distribution. This lens has an integral prism pattern designed so that
prisms face the lamp cavity and still supply superior photometrics. Highly recommended for all high tech manufacturing environments.
prisms face the lamp cavity and still supply superior photometrics. Highly recommended for all high tech manufacturing environments.
D
C
M O U N T I N G
D O O R F R A M E
A
B
C
D
3 3/4"
23 3/4"
23 3/4"
48"
95mm
602mm
602mm
1219mm
Shown With 1 1/2" T-Grid
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : C F D S F - 4 3 2 A - 1 2 0 - E B 8 1 - E L 4 - U
Series
CFD=Fluorescent
CFD=Fluorescent
Grid
Door Frame
FA=Flat White
FA=Flat White
Extruded
Aluminum Door
Aluminum Door
Number
of Lamps
2, 3, or
4 Lamps
of Lamps
2, 3, or
4 Lamps
(Not included)
Wattage (Length)
32=32W T8 (48”)
32=32W T8 (48”)
Lamp Type
A=#12 Pattern Acrylic
A125=#12 Pattern Acrylic
A=#12 Pattern Acrylic
A125=#12 Pattern Acrylic
(.125" Thick)
A19/156=#19 Pattern Acrylic
(.156" Thick)
KSH25
1
=Bat Wing Distribution
POLY12/125=#12 Pattern
Polycarbonate
(.125" Thick)
(.125" Thick)
Voltage
120=120V
277=277V
347=347V
UNV=120V
120=120V
277=277V
347=347V
UNV=120V
through
277V
277V
Ballast Type
LEOC8= Energy Saving
LEOC8= Energy Saving
Ballast
(T-8 Lamp
Only)
(T-8 Lamp
Only)
EB8 1= (1) Generic
Electronic
Ballast
Ballast
EB8 2= (2) Generic
Electronic
Ballast
Ballast
(For Specific Electronic
Ballast Specify Brand
and Catalog Number)
Ballast Specify Brand
and Catalog Number)
Options (add as suffix)
GL=Internal Single Element
GL=Internal Single Element
Fusing
EL4=Emergency Lighting
(Self-Contained)
RIF1=Radio Interference
Suppressor
EQ=T-BAR Safety
Earthquake Clips
PSI=200 PSI Hose Down
Rating
Accessories
(Order Separately)
EQ-Clip-U=Safety
(Order Separately)
EQ-Clip-U=Safety
Earthquake Clips
FAIL-SAFE
®
CLEANROOM
D E S C R I P T I O N
The Fail-Safe CFD Series
Cleanroom Troffer is
enclosed and gasketed to
maintain ceiling integrity
and protect against
infiltration of particles and
airborne bacteria. The
housing and door are
designed to work with 1"
and 1 1⁄2" inverted T-Grid
ceilings. The sealed, hole-
free housing prevents air
exchange between the
fixture and plenum and
allows relamping without
contamination of clean
areas. Dedicated to today’s
T8 lamp technology, these
luminaires are U.L. listed
and C.S.A. certified for wet
locations for covered ceiling
applications and are
manufactured in accordance
with U.S.D.A., F.D.A., and
Federal Standard 209E.
Suitable for use in I.E.S.
Class 1,000, 10,000 and
100,000 clean room
environments.
Cleanroom Troffer is
enclosed and gasketed to
maintain ceiling integrity
and protect against
infiltration of particles and
airborne bacteria. The
housing and door are
designed to work with 1"
and 1 1⁄2" inverted T-Grid
ceilings. The sealed, hole-
free housing prevents air
exchange between the
fixture and plenum and
allows relamping without
contamination of clean
areas. Dedicated to today’s
T8 lamp technology, these
luminaires are U.L. listed
and C.S.A. certified for wet
locations for covered ceiling
applications and are
manufactured in accordance
with U.S.D.A., F.D.A., and
Federal Standard 209E.
Suitable for use in I.E.S.
Class 1,000, 10,000 and
100,000 clean room
environments.
• Nominal 3 3⁄4" deep
recessed housing consists
of one-piece, code gauge,
prime cold rolled steel. The
hole-free embossed
housing has full length die
formed stiffeners for added
strength. End plates are
securely attached and
completely sealed
of one-piece, code gauge,
prime cold rolled steel. The
hole-free embossed
housing has full length die
formed stiffeners for added
strength. End plates are
securely attached and
completely sealed
• Standard Class P, CBM/ETL
ballast
• Electrostatically
applied
baked white polyester
powder enamel finish.
Minimum reflectance 90%.
Multistage cleaning cycle,
iron phosphate coating
with rust inhibitor
powder enamel finish.
Minimum reflectance 90%.
Multistage cleaning cycle,
iron phosphate coating
with rust inhibitor
• Die formed, heavy gauge,
extruded aluminum door
with reinforced corners and
baked white enamel finish.
Positive light seals
with reinforced corners and
baked white enamel finish.
Positive light seals
• Lens retained by one piece
continuous gasket secured
into door frame creating an
environmental seal
into door frame creating an
environmental seal
• Positive cam action spring
loaded, self-locking, black
steel latches. Safety-lock
hinges allow hinging and
latching on either side
steel latches. Safety-lock
hinges allow hinging and
latching on either side
• One piece continuous
gasket surrounds perimeter
of lens to seal lens to door
frame. Additional gasketing
seals door to housing
of lens to seal lens to door
frame. Additional gasketing
seals door to housing
D I M E N S I O N S
CFD
3 2 W
F l u o r e s c e n t
2 ' x 4 '
F L U O R E S C E N T G R I D
1474
COOPER LIGHTING