1.  Open the Door - 
Press both BUTTON LATCHES at the same time and open the door. 
See Figure 1.
2. Reflector Removal - 
Press the two REFLECTOR TABS  outward and 
swing the REFLECTOR down. 
See Figure 2a and Figure 2b.
NOTE: Disconnect REFLECTOR CONNECTOR from 
the HOUSING as shown in Figure 2c.
Customer First Center  •  1121 Hwy 74 South  •  Peachtree City, GA  30269
IMI-606    AVU040954
Mast Arm Adapter
Sheet 1 of 5
5/26/04
IMI-606
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
RETAIN FOR FUTURE REFERENCE.
General: Upon receipt of fixture thoroughly inspect for any
freight damage, which should be brought to the attention of
the delivery carrier. Compare the catalog description listed
on the packing slip with the fixture label on the housing to
assure you have received the correct merchandise.
Safety: This fixture must be wired in accordance with 
the national electrical code and applicable local codes 
and ordinance. Proper grounding is required to insure 
personal safety. Carefully observe grounding procedure. 
All work should be done by an electrician.
TM
WARNING: 
Risk of Electric Shock. Disconnect power at circuit breaker panel or 
fuse box before installing or servicing.