Cooper Lighting MPR2 Folheto

Página de 2
Catalog #
Project
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
03/18/2008 6:56:59 AM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADC080701
ORDERING INFORMATION
DESCRIPTION
Fail-Safe's hospital patient room of the future - the MPR removes lighting 
elements from walls incorporating them into a multi-compartment ceiling 
fixture. Sections provide independent task illumination: patient reading light 
using (1) 40W biaxial lamp puts the light at the head of the bed for patient 
use; ambient room light using (2) 40W biaxial lamps provides soft illumi-
nation via perforated wings while shielding direct source glare; examination 
light uses (3) 40W biaxial lamps and focuses high intensity illumination to 
torso for maximum patient appraisal with minimal wattage consumption. 
The system is designed for 1, 2, or 3 feeds potentially reducing the overall 
installed cost. Also available for 50W biaxial lamps.
Mounting
Recessed Grid or Flange, Ceiling 
Mount (supported from above)
Lamps
(By Others)
Ballast
Standard, Class P, CBM/ETL 
Ballast, (3) circuit wiring.
Housing
Die-formed, 20 ga. cold rolled 
steel.
Features
- 20 gauge CRS housing is formed 
  fabricated for maximum strength 
  and stability.
- Each compartment is designed to 
  provide a specific illumination 
  function while allowing for 
  commonality of branch circuit 
  feeding.
- High efficiency biaxial lamps 
  provide excellent color 
  rendering ability and high 
  lumen output for nominal 
  wattage draw.
Finish
Low gloss, electrostatically 
applied, baked white powder 
polyester-finish.
Shielding
(READING LIGHT) Die formed lamp 
shield. 
(AMBIENT LIGHT) Formed 
perforated metal.
(EXAM LIGHT) Pattern 12 Acrylic 
Ribbed lens.
Labels
U.L. Listed, C.S.A. Certified.
MPR
MPR2
AMBIENT/DIRECT
Multi-Compartment
Patient Room
Recessed Luminaire
2' x 4' Fluorescent Grid
2' x 4' Fluorescent Flange
E N E R G Y   D A TA
Input Watts:
Electronic Ballasts and 
Standard Lamps
(6) 40W Biaxial Fluorescents: 204W
(6) 50W Biaxial Fluorescents: 264W
S A M P L E   N U M B E R :   M P R 2 - G - 6 4 0 B X - 1 2 0 - E B X 3
Product Family
MPR2= 2 Compartment
Medical Patient
Room Recessed
Luminaire Exam
& Ambient
Section
MPR = Standard 3
Compartment
Medical Patient
Room Recessed
Luminaire
Reading, Exam
& Ambient
Section
Voltage
120=120V
277=277V
347=347V
UNV=120V through 277V
Options
EBP=Emergency
Battery Pack
FNL=Fluorescent
Night Light
(Lamp by others) 
GLR=Fuse and Holder
RIF=Radio
Interference
Filter
LVRELAY=Low
Voltage Relay
Ballast
EBX3
=(3) Ballasts for use with biaxial lamps
EBX4=(4) Ballasts for use with biaxial lamps 
1
Lamp Type
Biaxial Fluorescents 
640BX=(6) 40W Lamps
650BX=(6) 50W Lamps
Ceiling
Type
G=Grid
F=Flange
Ambient Options
If no option is chosen, then 
Standard 2 Basket Ambient
will be provided.
SCPB=Single Perf Basket Centered
SSCB=Single Sealed Lamp
Accessories (order
separately)
MPR-GGO-1=Full
Clear Poly Lens
Door. No Acrylic
Over Exam Hinged Door
2
MPR-GGD-2=Two
Compartment MPR
(Lens Poly and Acrylic)  
MPR-GGD-3=Three
Compartment MPR
Hinged Door (Lens
Poly and Acrylic) 
2
2
6” [153mm]
6” [153mm] MAX FROM WALL
24” [610mm]
48” [1219mm]
24” [610mm] wide
18” [457mm]
6 1/4”
[159mm]
AMBIENT LIGHT
READING
LIGHT
EXAM
LIGHT
3   C O M PA R T M E N T   M O U N T I N G
2   C O M PA R T M E N T   M O U N T I N G
3   C O M PA R T M E N T   D I M E N S I O N S
2   C O M PA R T M E N T   D I M E N S I O N S
24"
(4) 5/16" Mounting Holes
ø .875 
Knockout
6”
max.
6 1/4"
20 3/8"
44 1/8"
24" x 48" C to C
Runs Ambient Section
Exam Light
Runs Exam Section
FAIL-SAFE
®