Enviro 1200 Fireplace Freestanding Manual Do Utilizador

Página de 50
15
Specifications
C
LEARANCES
 T
O
 C
OMBUSTIBLES
 - 1700 F
REESTANDING
:
MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*
Single Wall Pipe
Double Wall Pipe**
Double Wall Pipe 
with Heat Efficiency 
Shield 50-1088 (Flat 
top model only)
Top vent out back 
wall with min. 48” 
(1220 mm) vertical 
rise; double wall
A From side wall
to side of unit
20”
(508 mm)
13”
(330 mm)
13”
(330 mm)
11”
(279 mm)
B From rear wall 
to back of unit
12”
(305 mm)
10” 
(254 mm)
7”
(178 mm)
13”
(330 mm)
C From adjacent wall 
to corner of unit
10”
(254 mm)
81⁄2”
(216 mm)
6”
(152 mm)
D From side wall
to collar
29”
(737 mm)
22” 
(559 mm)
22”
(559 mm)
20”
(508 mm)
E From rear wall 
to collar
15”
(381 mm)
13”
(330 mm)
10” 
(254 mm)
16”
(406 mm)
F
From adjacent wall 
to collar
181⁄2”
(470 mm)
17”
(432 mm)
141⁄2”
(368 mm)
G † From door opening
to edge of hearth pad
USA 16” (406 mm)
CND 18” (450 mm)
USA 16” (406 mm)
CND 18” (450 mm)
USA 16” (406 mm)
CND 18” (450 mm)
USA 16” (406 mm)
CND 18” (450 mm)
H † From side/back of unit
to edge of hearth pad
USA 6” (152 mm)
CND 8” (200 mm)
USA 6” (152 mm)
CND 8” (200 mm)
USA 6” (152 mm)
CND 8” (200 mm)
USA 6” (152 mm)
CND 8” (200 mm)
Alcove (48” Deep) 
I
Total Width
51” (1295 mm)
J
Total Height
72” (1829 mm)
K Top of stove to ceiling
44” (1118 mm)
L
Side wall to stove
13” (330 mm)
M Side wall to pipe
22” (559 mm)
N Back wall to unit
8” (203 mm)
O Back wall to pipe
11” (279 mm)
CAUTION: An uninsulated smoke pipe must not pass through an attic, roof space, closet or similar concealed 
space, or through a floor, ceiling, wall, or partition, or any combustible construction.
† FLOOR PROTECTION: If a stove is installed on a combustible floor, it must have a pedestal or leg kit with ash 
pan attached and be on a NON-COMBUSTIBLE hearth pad 
*  ALL CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO THE LOCAL AUTHORITY. 
**DOUBLE WALL: 
IN CANADA:  Any ULC-S629 listed chimney system with the accompanying listed double wall vent connector.
IN U.S.A.: Any UL 103 HT listed chimney system with the accompanying listed double wall vent connector.
�����
�����
������
J
���� ����
��
��
�����
������ ���� ����
��
��
��
��
��
��
�������� ����
��
��
��
I
������
Figure 8: 1700 Freestanding Clearance to Combustibles