Toshiba RAV-SP1104AT-E Manual Do Utilizador

Página de 162
– 120 –
Downward
discharge
Downward
discharge
Downward
discharge
Downward
discharge
Horizontal
discharge
Horizontal
discharge
Horizontal
discharge
Horizontal
discharge
Downward
discharge
Downward
discharge
Downward
discharge
Downward
discharge
Horizontal
discharge
Horizontal
discharge
Horizontal
discharge
Horizontal
discharge
3. How to set up type of swing
1
Push 
SWING/FIX
 for 4 seconds or more during stop
of the operation.
 flashes.
2
Push 
UNIT  
LOUVER
 (At the left side of the button)
and select the unit to be selected.
• Every pushing the button, the unit No. changes.
Swing setup code
REQUIREMENT
• Do not set 0000. (Louver may cause a trouble.)
4
Push 
SET
 .
5
Push 
TEST
 to finish the setup.
∗ Standard swing
Four louvers swing simultaneously with the same
angel.
The fan of the selected unit rotates and the louver swings.
3
Using TIMER  SET 
 / 
 buttons, select type of
the swing.
Swing setup code
0001
0002
0003
Louver operation
Standard swing (At shipment)
Dual swing
Cycle swing
∗ Dual swing
(Recommended for heating operation)
• The adjoined louvers repeat horizontal
discharge/Downward discharge alternately
to clear irregularity of the temperature in
heating operation.
• The vertical discharge spreads hot air to the
floor, and the horizontal discharge stirs.
Both suppress the temperature irregularity.
UNIT No.
1–1
UNIT No.
1–2
UNIT No.
1–3
UNIT No.
No display
UNIT No.
1–4
∗ Cycle swing
(Recommended for cooling operation)
• 4 louvers swing with time lag as if they
heave.
Swing