SM7100 Introduction
Programmable Timing Delays
A delay can be programmed between relay closures to allow for settling times of other system
resources. When used with triggers, a controlled synchronous switching system can easily be
configured.
Safety Interrupt
resources. When used with triggers, a controlled synchronous switching system can easily be
configured.
Safety Interrupt
This is a programmable fail-safe feature that allows all relays to open based upon the occurrence
of a selected TTL backplane trigger. This allows signals to be removed from the unit under test if
a system fail-safe occurs, such as inadvertent removal of a test adapter.
of a selected TTL backplane trigger. This allows signals to be removed from the unit under test if
a system fail-safe occurs, such as inadvertent removal of a test adapter.
SM7100
S
PECIFICATIONS
SM7000
S
PECIFICATIONS
M
AXIMUM
P
OWER
H
ANDLING
(CW)
At 18 GHz
20 W, 100 W peak pulse
S
WITCHING
T
IME
< 15 ms
RF
I
MPEDANCE
50 Ω
F
REQUENCY
(GHz)
dc – 3
3 – 18
18 – 20
Isolation (dB min)
Insertion Loss (dB max)
VSWR
90
80
60
1.0
2.8
3.0
1.2:1
1.6:1
2.0:1
S
WITCH
L
IFE
1,000,000 cycles per switch
C
ONNECTORS
SMA
P
OWER
R
EQUIREMENTS
+5 V @ 0.30 A
-5.2 V @ 0.10 A
-2 V @ 0.10 A
160 mA current draw per relay closure at +24 V
-5.2 V @ 0.10 A
-2 V @ 0.10 A
160 mA current draw per relay closure at +24 V
C
OOLING
R
EQUIREMENTS
2.22 L/s