6
2-2-2.  Outdoor Unit (2)
Outdoor unit   CG1411
Burner
Type
Ribbon burner
Q’ty … Material, thickness
inch (mm)
1 … Stainless steel, 0.0157 (0.4)
Nozzle
Q’ty … Material
1 … Brass
Diameter
ø inch (ø mm)
0.0807 (2.05 ± 0.05)
Fan & Fan Motor
Type
Sirocco fan
Q’ty … Dia. and length
inch (mm)
1 … ø 3.346 (85) and 0.984 (25)
Fan motor model … Q’ty
FU2-051FIMP … 1
No. of poles … rpm
2 … (1,300 – 2,900)
Nominal output
W
6
Coil resistance (ambient temp. 68°F (20°C))
Ω
21.3
Safety devices
Type
Thermal fuse
Operating temp.
Open °F (°C)
293 (145)
Close
Refrigerant Heater
Case / Coil
Aluminum (collapsible forming) / Copper tube
Heat conduction face area
ft
2
(m
2
)
1.83 (0.17)
Heat load
×
10
–3
BTU/h • ft
2
(m
2
)
7.65 (1.3)
Combination Gas Valve
Type
Combination control
Model
UP13-27
Coil resistance
Valve (SV1 & SV2 for shut-off)
Ω
1600 ± 10%
Valve (PV for control)
Ω
87 ± 10%
Igniter
Type
Electric sparking
Model
IG-XS07-S