Ask Proxima DP2400 Manual Do Utilizador

Página de 13
ASK Proxima Lamp Information Guide
C440
3500
2000 Hours
Press the Menu button and choose About.  If the 
maximum lamp time of 2000 hours is exceeded, the 
lamp will not light.  The lamp must be replaced and the 
lamp timer reset before the projector will operate.
Press the Menu Button, choose Settings, then 
choose Service, then Lamp Reset.  At 2000 hours, 
the lamp will not light (Lamp Error LED will be On).  
You must press and hold the "Volume -" button and 
the "Volume +" button simultaneously for ten 
seconds, then release.  Power LED on keypad will 
reset to green, and you can power the lamp on.
C450
4500
2000 Hours
Press the Menu button and choose About.  If the 
maximum lamp time of 2000 hours is exceeded, the 
lamp will not light.  The lamp must be replaced and the 
lamp timer reset before the projector will operate.
Press the Menu Button, choose Settings, then 
choose Service, then Lamp Reset.  At 2000 hours, 
the lamp will not light (Lamp Error LED will be On).  
You must press and hold the "Volume -" button and 
the "Volume +" button simultaneously for ten 
seconds, then release.  Power LED on keypad will 
reset to green, and you can power the lamp on.
DP1000x
1100
3000 Hours
Press Menu Button, choose Setup, then choose 
Service, then Info.  At 2900 hours the Lamp LED lights.
Press Menu Button, choose Setup, then choose 
Service, then Reset Lamptimer.  Press Select button 
again to confirm reset.  This will turn off the Lamp 
LED also.
DP1200x
1100
2000 Hours
Press the Menu Button, then choose About.  If the 
maximum lamp time of 2000 hours is exceeded, the 
lamp will not light.  The lamp must be replaced and the 
lamp timer reset before the projector will operate.
Press the Menu Button, choose Settings, then 
choose Service, then Lamp Reset.  If reached 2000 
hour life, Press and Hold the "Volume+" button and 
then Press the  "Volume -" button and hold for ten 
seconds to reset.
DP2000s
1000
2000 Hours
Press the Menu button and choose About.  If the 
maximum lamp time of 2000 hours is exceeded, the 
lamp will not light.  The lamp must be replaced and the 
lamp timer reset before the projector will operate.
Press the Menu Button, choose Settings, then 
choose Service, then Lamp Reset.  If reached 2000 
hour life, must Press and Hold the "Volume+" button 
and then Press the  "Volume -" button to reset.
DP2000x
1300
2000 Hours
Press the Menu button and choose About.  If the 
maximum lamp time of 2000 hours is exceeded, the 
lamp will not light.  The lamp must be replaced and the 
lamp timer reset before the projector will operate.
Press the Menu Button, choose Settings, then 
choose Service, then Lamp Reset.  If reached 2000 
hour life, must Press and Hold the "Volume+" button 
and then Press the  "Volume -" button to reset.
DP2300
45
40 Hours
N/A
N/A
DP2400
90
40 Hours
N/A
N/A
Copyright InFocus Corp.