9.   Install the flex pipe assembly through the wall thimble, ensure that this portion of pipe slides through 
the outside wall far enough to connect onto the vent termination cap.
10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar 
adaptor previously installed into the fireplace flue outlet.  Slide the Ø4” (10 cm) flex vent over the flue 
collar and secure with three (3) sheet metal screws evenly spaced.
11. Place a bead of high temperature silicone on the intake collar of the fireplace, slide the Ø6⅝” (16.25 
cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly 
spaced.
12. On the outside of the exterior wall, apply a bead of Mill-Pac Black sealant to the Ø4” (10 cm) pipe of 
the vent terminal.  Slide the flex liner onto the vent terminal and secure with three (3) sheet metal 
screws evenly spaced.
13. Place a bead of high temperature silicone on the intake collar of the vent terminal, slide the Ø6⅝” 
(16.25 cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws 
evenly spaced.
14. Attach the vent terminal to the outside of the house using four (4) wood screws provided. 
15. Light the appliance and ensure proper operation.
o
theR
 a
PPRoveD
 v
ent
 P
aRts
:
Table 3: Approved Vent Manufacturers
Manufacturer
Trade Name
Nominal Sizes
American Metal Products
AmeriVent Direct
4” - 6 5/8”
Security Chimneys International LTD
Secure Vent
4” - 6 5/8”
Selkirk Metalbestos
Direct-Temp
4” - 6 5/8”
Simpson Dura-Vent
Direct Vent GS
4” - 6 5/8”
The  DV42DX  fireplace  has  been  tested  and  certified  for  use  with  AMERICAN  METAL  PRODUCTS 
“AMERIVENT DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES.  SECURITY CHIMNEY’S 
“SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available 
for  horizontal  and  vertical  venting.    When  using  Simpson  Duravent,  it  is  recommended  that,  before 
installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-
Pac to each inner joint.  When planning an installation, it will be necessary to select the proper length of 
vent pipe for the particular requirements.  
WARNING: Do not mix parts from different vent manufacturers’s systems.
EXCEPTION  TO WARNING:   This product has been evaluated by Intertek  for using a Direct  Vent GS 
starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems.  Use 
of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the 
Intertek WH listing of the appliance.
Initial Installation
QUALIFIED INSTALLERS ONLY