Number  Description
E58-45 
45° Elbow, Galvanized
E58-90 
90° Elbow, Galvanized
FSE58-45 45° Starter Elbow (Dura Vent to 
 
FMI Pipe)
FP-58 
Firestop Plate
WF-58 
Wall Firestop, Galvanized
RF-58-6  Roof  Flashing  -  0  to  6/12  Pitch,  
 
Galvanized
RF-58-12  Roof Flashing - 6/12 to 12/12 Pitch,  
 
Galvanized
S-58 
Vinyl Siding Standoff, 
 
Galvanized
VT-58 
Vertical  Round  Termination,  
 
Galvanized
HHT-58 
High  WInd  Round  Horizontal 
 
Termination Kit, Galvanized
HTS-58 
Square  Horizontal  Termination,  
 
Galvanized
HHTK-58  High  Wind  Round  Horizontal 
 
Termination Kit 
 
(Includes  Round  Termination,  
 
Wall Firestop, 45° Elbow)
ST-58-14  14" Snorkel Termination, 
 
Galvanized
ST-58-36  36" Snorkel Termination, 
 
Galvanized
SF-58 
Stucco Flashing - 
 
For use with HTS-58
VR-58 
Vertical Restrictor, Galvanized
WS-58 
Wall Strap
SC-58 
Storm Collar, Galvanized
CS-58 
Cathedral Ceiling Support
VENTING INSTALLATION 
INSTRUCTIONS
Continued
INSTALLATION
WALL SWITCH INSTALLATION
The electronic version uses a 24 VAC current sup-
plied from a transformer mounted on the ignition 
module and is prewired for easy connection to a 
wall switch (see Figure 31). The millivolt version 
uses a self generated millivolt current that allows 
you to activate the gas control valve directly with-
out the use of normal household electricity (see 
Figure 32). Both versions are supplied with a wall 
switch kit for ready connection and mounting.
  WARNING:  Do  not  wire  re-
mote wall switch to main power 
supply  (Standard  120V  house-
hold current).
V1
SW
SI
TS
IND
V2
L1
D
N
G
P.
Figure 31 - Wall Switch Wiring Diagram, 
Electronic Units
Route 24V (Supplied)
Through Electrical 
Conduit Bushing
Electrode
Transformer
Plug 120V AC
To Receptacle
18 AWG 
Red Wire
Wall Switch
(Supplied)
Make Connections 
with Wirenuts 
(Supplied)
Ignition 
Control 
Module
(Back 
View)
V1
SW
SI
TS
IND
V2
L1
D
N
G
P.
Figure 32 - Wall Switch Wiring Diagram, 
Millivolt Units
Note:
 If any of the original wire supplied must be 
replaced, use type 18 AWG-105° C (25 feet length 
maximum) or equivalent.
OFF
  P
IL
O
 ON 
LO
        HI 
PI
LOT 
E
A
16AI
7
TPTH        
TP
         
TH
Wall Switch 
(Supplied)
Route Millivolt Wires 
(Supplied) Through Gas 
Line Conduit Sleeve
To 
Thermopile
(Back 
View)
OFF
  P
IL
O
 ON 
LO
        HI 
PI
LOT 
E
A
16AI
7
TPTH        
TP
         
TH
1.  To remove the louvers, simultaneously pull 
both top end spring latches towards the center 
of the appliance until they are disengaged 
from locating holes. Repeat for bottom spring 
latches and pull louvers outward. Reverse the 
procedure to install louvers back onto the ap-
pliance (see Figure 33, page 19).
2.  Connect the 18 gauge wires from wall switch 
to the gas control valve terminals marked TH 
and TPTH or to the ignition module using the 
pigtails and wire nut connectors supplied with 
the appliance.