Desa (V)DVF36TCRP(E) Manual Do Utilizador

Página de 36
www.desatech.com
112108-01C
31
TROUbLESHOOTING
Continued
REMEDY
1. Check ignition wire connec-
tion (see Wiring Diagrams)
2. Check ground wire connection 
(see Wiring Diagrams)
3. Clean and adjust main burner; 
check  gas  supply  and  inlet 
pressure; replace ignition as-
sembly if necessary
1. Check electrical connections 
and replace wall switch
1. Clean and adjust main burner 
2. Adjust  ignitor  location  for 
maximum flame impingement 
on sensor
3. Have vent inspected for block-
age or damage
POSSIBLE CAUSE
1. Loose  wiring  on  ignition 
module
2. Poor  ground  to  ignition 
module
3. Main burner flame too low 
to sense
1. Wall  switch  wires  defec-
tive
1. Burner flame is too low
2. Igniter is misaligned causing 
safety burner to "drop out"
3. Vent  may  be  blocked  or 
restricted
 PROBLEM
Burner will not stay lit
No gas to main burner when wall 
switch and valve are set to ON 
position
Frequent main burner outage
WIRING DIAGRAMS
GND
J. BOX RECEPTACLE
GRN
BLK
WHT
BREAKER)
GRN
(NOT SUPPLIED)
INCOMING
120V AC
(FUSE BOX
FIELD WIRE
WHT
BLK
OR
CONNECTORS
Variable
Speed
Control
Blower
Electrical Rating:
120v, 60Hz, 0.7A
TRANSFORMER
STEP DOWN
120V AC
24V AC
OFF
WALL SWITCH
(SUPPLIED)
ON
IGNITER
ASSEMBLY
D V2
G
N
L1 IND
IGNITION CONTROL 
MODULE
TS S1
SW V1
P.
120 VAC
GND
J. BOX RECEPTACLE
OPTIONAL
CONTROL
REMOTE
GRN
BLK
WHT
BREAKER)
GRN
(NOT SUPPLIED)
INCOMING
120V AC
(FUSE BOX
FIELD WIRE
WHT
BLK
OR
CONNECTORS
E
A
I
H
L
O
I
P
T
O
L
CONNECT
VALVE TO
CONTROL
DO NOT
GAS VALVE
Figure 60 - Electronic Wiring Diagram
Figure 61 - Optional Blower Wiring Diagram