CLEANING AND 
MAINTENANCE
 WARNING: Installation and 
repair should be done by a quali-
fied service person. The appli-
ance should be inspected before 
each use and at least annually 
by  a  qualified  service  person. 
More frequent cleaning may be 
required  due  to  excessive  lint 
from carpeting, bedding mate-
rial, pet hair, etc. It is imperative 
that the control compartments, 
burners and circulating air sys-
tem be kept clean.
 WARNING: The logs can be 
hot. Handle only when cool.
TO TURN OFF GAS 
TO APPLIANCE
1.  Turn off all electric power to the appliance 
if service is to be performed.
2.  Remove control access panel.
3.  Close the gas valve.
OPERATING FIREPLACE
Continued
Figure 26 - Pilot
 WARNING: Turn off gas and 
electrical power before servicing 
appliance.  Any  safety  screen 
or guard removed for servicing 
must be replaced prior to operat-
ing the appliance.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
Keep control compartment, logs, burner and area 
surrounding logs clean by vacuuming or brushing 
at least twice a year. Take care not to alter the set-
tings on the pilot assembly.
Do not use abrasive liquids or cleaners for cleaning 
glass doors and trims. Any household glass cleaner 
should suffice. Do not clean doors when hot. Allow 
appliance to cool before cleaning.
TECHNICAL SERVICE
You may have further questions about installation, 
operation or troubleshooting. If so, contact DESAʼs 
Technical Service Department at 1-866-672-6040. 
When calling please have your model and serial 
numbers of your heater ready.
You can also visit DESAʼs Technical Services web 
site at www.desatech.com
SPECIFICATIONS
GL36PN, GL36PNE
•  Maximum Input Rating at Altitudes: 2,000 ft. 
- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800 
Btu/hr.
•  Manifold Pressure: 3.5 W.C. (.87 kPa)
•  Supply Pressure (in. of water): Minimum* - 4.5" 
(1.12 kPa), Maximum - 11.0" (2.74 kPa)
•  Orifice Size at Altitudes: 2,000 ft. - #30, 2,000 ft. 
to 4,000 ft. - #31
* For the purpose of input adjustment
GL36PNP, GL36PNEP
•  Maximum Input Rating at Altitudes: 2,000 ft. 
- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800 
Btu/hr.
•  Manifold Pressure: 11.0 W.C. (2.74 kPa)
•  Supply Pressure (in. of water): Minimum* - 
12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)
•  Orifice Size at Altitudes: 2,000 ft. - #49, 2,000 ft. 
to 4,000 ft. - #51
* For the purpose of input adjustment