Aquacal 121 Manual Do Utilizador

Página de 214
50
 Controls Configuration & Adjustments...
Microprocessor Factory Default Settings
Level –1 and Level-2 Default Settings
Microprocessor Level-2 Set Up & Calibration Codes
Service Adjustable Parameters
Code Description  Factory 
Setting 
Range 
[LOC] 
Service Lock Code 
50 
00-99 
[dEL] 
4-minute Delay on Make 
0 / 1 
[JAO] 
External Controller Interface 
0 / 2 / 3 
[FS2] 
Flow Switch/Auto T-Stat Switching 
0 / 1 
[tSC] 
Water Sensor Calibration 
Factory Calibrated 
+10
o
 to –10
o
 of display 
[dSC] 
Defrost Sensor Calibration 
Factory Calibrated 
+10
o
 to –10
o
 of display 
[dBS] 
Spa Dead Band Differential 
1
o
 
1
o
 to 5
o
[dBP] 
Pool Dead Band Differential 
1
o
 
1
o
 to 5
o
Menu Code 
Description 
Default 
Value 
Range 
Level-1 
[CF1] 
Celsius/Fahrenheit 
0 / 1 
Level-1 
[ULC] 
User Lock Code 
0 / 1 
Level-1 [ELC] 
Enter 
Lock 
Code 
00-99 
Level-1 
[CFO] 
Call / Flex 
0 / 1 / 2 
Level-1 [LOC] 
Service 
Lock 
Code 
50 
00-99 
Mode Key 
Pad 
Operating 
Mode 
OFF 
For Heat Only: OFF/HEAT 
For Heat & Cool: 
OFF, HEA, COO, ACH 
Thermostat 
Key Pad 
Thermostat Settings Pool & Spa 
OFF 
45
o
F – 104
o
F
Level-2 [dEL] 
Anti-Short Cycle, 4-minute Delay 
on Make 
1
0 / 1 
Level-2 
[JAO] 
External Controller Interface 
0 / 2 / 3 
Level-2 [FS2] 
Flow Switch / Automatic 
Thermostat Switching 
0 / 1 
Level-2 
[tSC] 
Water Sensor Calibration 
Factory Calibrated 
+10
o
 to –10
o
 of displayed 
value 
Level-2 
[dSC] 
Defrost Sensor Calibration 
Factory Calibrated 
+10
o
 to –10
o
 of displayed 
value 
Level-2 
[dBS] 
Spa Dead Band Differential 
1
o
 
1
o
 to 5
o
Level-2 
[dBP] 
Pool Dead Band Differential 
1
o
 
1
o
 to 5
o