Indesit IPG751SBKGB Guia Do Utilizador

Página de 16
GB
4
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
• Setting the burners to minimum:
1. Turn the tap to the low flame position.
2. Remove the knob and adjust the adjustment screw,
which is positioned in or next to the tap pin, until the
flame is small but steady.
3. Having adjusted the flame to the required low setting,
while the burner is alight, quickly change the position of
the knob from minimum to maximum and vice versa
several times, checking that the flame does not go out.
4. Some appliances have a safety device (thermocouple)
fitted. If the device fails to work when the burners are
set to the low flame setting, increase this low flame
setting using the adjusting screw.
5. Once the adjustment has been made, replace the seals
on the by-passes using sealing wax or a similar
substance.
! If the appliance is connected to liquid gas, the regulation
screw must be fastened as tightly as possible.
! Once this procedure is finished, replace the old rating
sticker with one indicating the new type of gas used.
Stickers are available from any of our Service Centres.
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet pipe (in order
to comply with current national regulations).
Electrical
connections
DATA PLATE
see data plate
This appliance conforms to the following 
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low 
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04 
(Electromagnetic Compatibility) and 
subsequent amendments
- 93/68/EEC dated 22/07/93 and 
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and 
subsequent amendments.
- 2002/96/EC and subsequent 
amendments.