Philips BDL9870EU/00 Manual Do Utilizador

Página de 42
BDL9870EU
19
•  DNS2
•  MAC address
•  Login user name (The default user name is {admin})
•  Login password (The default password is {0000})
DMR
Receive multimedia files from the connected device by your network.
Clear internet memory
Clear all the cookies, bookmarks, history list and text used for filling
automatically.
Configuration1 reset
Reset all settings in Configuration1 menu to the factory preset values.
Factory reset
Reset all settings in the OSD menus of {Picture}, {Screen}, {Audio}, {PIP},
{Configuration1}, {Configuration2}, and {Advanced option} to the
factory preset values.
Press [ ]
 
or [ ] button to select {Reset}, and press [OK] button to
do the reset.
Factory reset
Cancel
Reset
5.2.6.  Configuration2 menu
Input
Advanced option
Configuration 2
OSD H-position
OSD V-position
Logo
OSD rotation
OSD turn off
Information OSD
Monitor ID
Monitor information
DP Version
Heat status
50
50
45
10 Sec.
Action
Action
Action
On
Landscape
DP 1.2
OSD turn off
Set the period of time the OSD (on-screen display) menu stays on the
screen.
The options are: {0 ~ 120} seconds.
OSD H-position
Adjust the horizontal position of the OSD menu.
OSD V-position
Adjust the vertical position of the OSD menu.
Information OSD
Set the period of time the information OSD is displayed on the upper
right corner of the screen. The information OSD will display when input
signal is changed.
The information OSD will remain on the screen with {Off} selection.
The options are: {Off, 1 ~ 60} seconds.
Logo
Enable or disable to show the
logo when you turn on the
display.
OSD rotation
Rotate the OSD Menu.
The options are:
•  {Landscape} (Default)
•  {Portrait}
Monitor ID
Set the ID number for controlling the display via the RS232C
connection. Each display must have a unique ID number when multiple
sets of this display are connected. Monitor ID number range is between
1 to 255.
The option are: {Monitor group} / {Tiling matrix} / {Auto ID}
Monitor Id
Monitor Id
Monitor group
Tiling matrix
Auto ID
1
1
1
End
•  {Monitor group}
The options are: {1-255}. The default setting is 1.
•  {Tiling matrix}
Tiling matrix number range is between 1 to 15. 1 is default setting. 
The {Auto ID} setup function enables setting up {Monitor ID} of
connected machine according to {Tiling matrix} settings.
Example: Tiling matrix sets as 4
1
2
5
6
3
4
7
8
9
10
11
12
13
14
15
16
•  {Auto ID}
The option are: {Start} / {End}. The default is {End}.
•  Switch to Start option to set up IDs of machines backward
from current one.
•  Once the setup is completed, the option exits to End
automatically.
•  To use this function, serial connect all machines with RS-232
cable and set their Control ports to RS-232, too.
Heat status
This function allows you to check the thermal status of the display at