Empire Comfort Systems VFD26F3-1 Manual Do Utilizador

Página de 32
Page 23
23466-0-0407
Label all wires prior to disconnection when servicing controls. 
Wiring errors can cause improper and dangerous operation. Verify 
proper operation after servicing.
Millivolt thermopile is self powered, gas valve does not require 110 
volts. Maximum length of 20 feet of 16 AWG to conductor wires 
is to be used with all optional components.
Use  the  two  leads  (Green  and  Red  wires)  to  attach  optional 
components.
Check 750 Millivolt System Operation
Millivolt system and all individual components may be checked 
with a millivolt meter 0-1000 MV range.
Remote Receiver
Use the following steps to place the remote receiver adjacent to 
the gas valve.
Attention:  The  remote  receiver  bracket  is  not  used  in  this 
installation.
1.  The remote receiver can not be placed behind the gas valve 
and burner assembly.
2.  When facing the appliance, the remote receiver must be placed 
to the right of the gas valve and burner assembly.
Note: Do not let remote control receiver come in contact with 
burner assembly.
On circulating vent-free firebox, install remote control receiver 
behind bottom louver.
Refer to remote control installation and operating instructions for 
more details on remote control.
(A)VFD26F3 WIRING
REMOTE/OFF/ON SWITCH
A DISTANCE/FERME/OUVERT
INTERRUPTEUR
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT