FMI M36EP(B,H) Manual Do Utilizador

Página de 32
www.fmiproducts.com
108796-01UT
9
INSTALLING TRANSITION PIPE AND 
STARTER COLLAR
The transition pipe and starter collar shown 
in Figure 9 are supplied with fireplace, unat-
tached  and  ready  for  installation.  Remove 
starter collar and set aside. Slide transition 
pipe over vent collar and attach with a mini-
mum of three screws. Replace starter collar 
over  transition  pipe  and  attach  using  four 
screws located on leg stands (five used on 
model M42E). To install B-vent piping, slide 
first piece of B-vent over transition pipe and 
attach with either a minimum of two screws 
or other means approved by the vent manu-
facturer.
Figure 9 - Installing Transition Pipe and 
Starter Collar
B-Vent Piping
Transition Pipe
Starter Collar
Vent Collar
PreINstallatIoN PreParatIoN
Continued
VeNtING INstallatIoN
at 60° or greater. The total vertical height in 
this example represents the minimum height 
of 8 feet and therefore the allowable lateral 
is  6  feet  when  the  75%  rule  applies.  If  the 
lateral  length  must  exceed  75%  then  the 
system must be sized in accordance with the 
Category I venting tables.
Example 2: Shows a multiple offset each at 
45° of inclination. Multiple offsets are permit-
ted if they do not exceed 45° of inclination. The 
total lengths of the two offsets are not required 
to meet the 75% allowable rule.
Example 3: Shows a single offset at 45° of 
inclination and therefore the lateral length at 
10 feet of offset does not have to meet the 
75% rule.
In each case the offsets must be supported 
and  firestops  must  be  positioned  wherever 
the vent must pass through a sub-floor, ceil-
ing joist or an attic overhang. The vent pipe 
must terminate vertically into a listed type vent 
cap  and  extend  a  sufficient  height  through 
an approved roof flashing, roof jack or a roof 
thimble. At  all  points  the  listed  clearances 
must be maintained.
Vent  terminations  must  be  located  in  ac-
cordance with height and proximity rules of 
NFPA No. 54. These rules apply to vents at 
12" diameter or less and require a minimum 
height in accordance with the roof pitch and a 
minimum of 8 ft. distance from a vertical wall 
or obstruction (see Figure 11, page 10).
A B-type venting system must be connected 
to  appliance  for  venting  to  the  outside  of 
building.
The following section is provided as a guide 
to a standard B-type vent installation.
Standing codes requirements concerning B-
type vent installations may vary within your 
state,  province  or  local  codes  jurisdiction. 
Therefore, it is recommended that you check 
with  your  local  building  codes  for  specific 
requirements or in absence of local codes, 
follow Section 7.0 of the current National Fuel 
Gas Code ANSI Z223.1/NFPA 54.
This  gas  appliance  must  be  vented  to  the 
outdoors only and may not be terminated into 
an attic space or into a chimney flue servicing 
a solid-fuel burning appliance.
This  appliance  may  be  vented  through  a 
manufactured chimney system or a masonry 
chimney using a B-vent adapter or a chim-
ney  liner  system  if  all  are  listed,  inspected 
and approved by local codes and/or building 
authorities.
The examples shown in Figure 10, page 10 
are  typical  of  most  B-vent  installations  and 
codes practices.
Example 1: Shows the minimum allowable 
system height and lateral offset for a 60° or 
greater inclination. Code specifies that offsets 
at  60°  or  greater  are  considered  horizontal 
and  must  follow  the  75%  rule  for  lateral  to 
total  vertical  system  height.  Codes  also  al-
low only one offset in the total system when