11.3 
economy Filtration/heating Modes (all Models)
Economy filtration/heating modes (F4-F6) are typically selected by 
customers in warm climates where heat up times are minimized due 
to higher ambient temperatures. In either of these modes, the water 
temperature is regulated by the set temperature, low-speed pump or 
optional circulation pump, and heater only while a programmed filtration/
heating cycle is running. 
note: These modes can be used to conserve energy while on vacation 
or out of town for several weeks since heater operation is minimized. 
During such times, you can also minimize the spa set temperature to 
maximize energy savings!
11.4 
lock modes - l1-l2 (all models)
These modes are designed for use during spa service or to prevent 
unauthorized use.
11.5 
selecting the Filtration/heating Mode
Press and hold both control panel WARMER ( ) and COOLER ( ) 
buttons at the same time, then release. Then press either WARMER  
( ) or COOLER ( ) button to select either filtration/heating mode or 
lock mode as outlined below.
11.6 
Filtration modes for spas without Circulation pump option 
(all models)
If your spa is equipped with the circulation pump option, disregard this 
section and refer to page 30 for filter cycle programming details.
standard Filtration/heating Modes (F1-F3)
(Heater automatically turns on during any heat call while in any Standard 
mode).
F1  4 hours of filtration/heating per day (one 2-hour cycle 
every 12 hours).
F2  6 hours of filtration/heating per day (one 2-hour cycle 
every 8 hours).
F3  8 hours of filtration/heating per day (one 2-hour cycle 
every 6 hours)
economy Filtration/heating Modes (F4-F6)
(Heater can only turn on during an active filter cycle while in any 
economy mode).
F4  4 hours of filtration/heating per day (one 2-hour cycle 
every 12 hours).
F5  6 hours of filtration/heating per day (one 2-hour cycle 
every 8 hours).
F6  8 hours of filtration/heating per day (one 2-hour cycle 
every 6 hours)