• If these do not solve the problem, re-flash the 
storage adapter and re-install the Windows 
2000/XP/Server 2003 driver. See 
Configuring 
and updating drivers
 on page 21.
If the devices connected to the Celerity FC 
storage adapter are not accessible 
1
Right-click My Computer.
2
Select Properties.
3
Select the Hardware tab 
4
Select Device Manager.
5
If the Celerity FC storage adapter does not 
appear under the SCSI and RAID controllers, 
shut down and make sure the Celerity FC 
storage adapter is properly seated in the PCI 
slot.
 a. Remove power from the PC.
 b. Remove its case.
 c. Check the PCI slot.
 d. Replace the case.
 e. Apply power. 
6
Reload the driver (see 
Configuring and 
updating drivers
 on page 21).
7
If the adapter has been identified but there is an 
exclamation point (!) on the listing, right click on 
the listing and select Uninstall
8
Reboot the system and repeat the installation 
process. 
9
If problems persist, contact your authorized 
ATTO Technology representative.
Linux
1
Verify the celerityfc driver is loaded with the 
lsmod 
command. If lsmod does not show the 
driver, refer to the installation instructions to 
install and load the driver in 
Configuring and 
updating drivers
 on page 21.
2
Check the system log with the command 
dmesg
. The celerityfc driver creates status 
messages during initialization. Make sure that 
all installed cards are properly detected and 
initialized.
3
Examine the contents of the file(s) 
/proc/scsi/celerityfc/X, where X is the 
adapter’s host number. This file contains details 
such as link status, connection speed and 
discovered devices.
Note
Advanced users only. Modify the driver 
makefile
 to enable debugging information. 
Upon loading, the celerityfc driver displays 
detailed debugging information which may 
help troubleshoot the problem.