Paradyne CSU Manual Do Utilizador

Página de 470
8. Troubleshooting
8-4
  
September 
2002
9128-A2-GB20-80
Restoring Communication with an Improperly Configured Unit
Configuring the unit improperly could render the menu-driven user interface 
inaccessible. If this occurs, connectivity to the unit can be restored via a directly 
connected asynchronous terminal.
Procedure
 
To reset COM port settings:
1. Configure the asynchronous terminal to operate at 19.2 Kbps, using character 
length of 8 bits, with one stop-bit, and no parity. In addition, set Flow Control to 
None.
2. Reset the unit, then hold the Enter key down until the System Paused screen 
appears. (See 
 
for other methods of resetting the unit.)
3. Tab to the desired prompt, and type y (Yes) at one of the prompts.
If no selection is made within 30 seconds, or if No (n) is entered, the unit 
resets itself and no configuration changes are made.
Once the unit resets itself, connectivity is restored and the Main Menu screen 
appears.
If selecting . . . 
The following occurs . . .
Reset COM Port usage
„
Port Use is set to Terminal so the asynchronous 
terminal can be used.
„
Data Rate (Kbps), Character Length, Stop Bits, and 
Parity are reset to the factory defaults.
„
Unit resets itself.
Reload Factory Defaults
„
All configuration and control settings are reset to the 
Default Factory Configuration, overwriting the 
current configuration.
„
Unit resets itself.
CAUTION: This causes the current configuration to be 
destroyed and a self-test to be performed.