B. SNMP MIBs and Traps, and RMON Alarm Defaults
B-18
  
September 
2002
9128-A2-GB20-80
RMON Alarm and Event Defaults
The FrameSaver unit supports automatic generation of RMON alarm and event 
information. Each alarm sets an SNMP variable to monitor. When the threshold set 
for the monitored variable is exceeded, an SNMP trap or a log event is sent.
Event Defaults
Since all events sent are under the control of the FrameSaver unit, there is no 
need to define multiple events for each alarm type, so only the following two events 
need to be generated:
The alarm default tables starting on the next page show how each RMON default 
alarm is set by the FrameSaver unit, shows the alarm and event types, the interval 
used when generating alarms, and thresholds.
„
„
„
„
 on page B-8 for information about 
how traps work, and 
 on page B-16 for traps specific to 
remote monitoring.
Dial Control Extension MIB
dialCtlPeerCall- 
Rejected
„
callHistoryPeerId 
(RFC 2128)
„
callHistoryPeerIfIndex 
(RFC 2128)
„
callHistoryLogicalIfIndex 
(RFC 2128)
„
callHistoryPeerAddress 
(RFC 2128)
„
devLastTrapString 
(devHealthAndStatus.-
mib)
A peer-to-peer call was not 
successful; the call was rejected 
by the far end.
„
ISDN Call Profile has been 
disabled.
„
This unit’s phone number was 
not in the far end device’s ISDN 
Call Profile.
String: 
‘Call on $ifString using B-Chnl 
$channel rejected by remote.’
Table B-9.
dialControl Traps (2 of 2) 
Trap
Variable-Bindings
Possible Cause
eventIndex
eventDescription
eventType
eventCommunity
65533
Default SLV Rising Event
log-and-trap(4)
0
65534
Default SLV Falling Event
log-and-trap(4)
0