Paradyne CSU Manual Do Utilizador

Página de 470
4. Configuration Options
9128-A2-GB20-80
September 2002
4-53
Time Slot Assignment Rule:
Valid network time slots are either Available or contain a Frame Relay Link 1 
assignment.
Procedure
 
1. Follow this menu selection sequence:
Main Menu
Configuration
Time Slot Assignment
 
Frame Relay Network Assignments
The Frame Relay Network Assignments screen appears. This screen contains 
a matrix of the current assignment status of all time slots on the network 
interface.
2. Enable or disable Time Slot Discovery. 
— When enabled, the unit examines all time slots not cross-connected to 
other ports to determine which time slots are being used by the network 
for frame relay traffic. These time slots are set to FrameRly1. This is the 
factory default. 
— When disabled, time slot assignments must be manually configured.
3. If Time Slot Discovery is disabled, assign network time slots for use by frame 
relay service, link 1, by typing FrameRly1 in the selected Network field.
4. Repeat Step 3 until all desired time slots are assigned. 
5. Save the configuration.
Assigning DSX-1 Time Slots to the Network Interface
DSX-1 time slots are assigned by channel allocation, where you specify individual 
time slots. The DSX-1 interface must be enabled to assign DSX-1 time slots to the 
network interface (see 
Value
Meaning
N
tt
It represents time slot 
tt  of the selected network interface.
Assigned
The time slot is already assigned to something other than a DSX-1 
time slot, so it is unavailable. Assigned time slots cannot be modified 
from this screen.
Available
The time slot is currently unassigned.
DSX-1/
tt
Slot 
tt of the DSX-1 interface is assigned to the network interface 
time slot identified right above it (N
tt).