Ashly CLX-52 Guia De Especificação

Página de 2
CLX-52
The unit shall be a dual channel compressor lim-
iter with independent gain, threshold, ratio, attack, 
release, and output level adjustments. It shall have 
a detector patch point allowing for the connec-
tion of an external equalizer in the detector loop 
to produce frequency selective limiting; or allows 
the connection of an external microphone source 
to produce voice-over-compression. It shall have 
front panel mounted switches for engaging/defeat-
ing the compressor/limiter functions. It shall have 
front panel switches for selecting input or output 
meter display. It shall have both XLR and 1/4” 
connectors on inputs and outputs. Performance 
specifications shall meet or exceed the following: 
Gain control shall be ± 15dB. Threshold shall be 
adjustable from -40dB to +22dB. Ratio shall be 
adjustable from 2:1 to infinity. Attack time shall be 
adjustable from 200uSec to 20mSec. Release time 
shall be adjustable from 100mSec to 3 seconds. the 
output level shall be adjustable from minus infin-
ity to +18dBu. The maximum in-out level shall be 
+23dBu. The input impedance shall be 20K ohm 
balanced bridging. The output impedance shall be 
200 ohm servo-balanced. The frequency response 
shall be 20Hz to 20KHz, +/-0.2dB. Distortion shall 
be <0.01% THD, 1KHz @0dBu, and <0.15% THD 
@ +15dBu from 20Hz to 20KHz. Hum and noise 
shall not exceed -96dBu @ unity gain. The unit 
shall operate at 100 - 240VAC +/-5%, 50-60Hz. 
The unit shall be designed for mounting in a stan-
dard EIA 19” rack (19”L x 1.75”H x 8”D) and shall 
have a shipping weight of 8 lbs. The unit shall be a 
CLX-52 Compressor Limiter by Ashly Audio, Inc. No 
other unit shall be acceptable unless submitted data 
from and independent research lab verifies that the 
above size/performances specifications are met.
ARCHITECTS SPECIFICATIONS
TECHNICAL NOTES & SPECIFICATIONS
CLX-52 Peak Compressor/Limiter
Features:
• XLR and 1/4” Connectors
• Peak Compression Circuitry
• Precision Balanced Inputs
• Extremely Low Noise and 
Distortion
• Calibrated Threshold Control
• Detector Patch Point
• Input-Output Meter Switch
• Gain Reduction Meters
• Stereo Tie Switch 
• Safety/Compliance: cTUVus/CE, RoHS
• 5-Year Worry-Free Warranty
Typical Applications
The applications of the Ashly CLX-52 can be divided into two basic categories, limiting and compressing. When used as a protective device it 
is functioning as a Limiter. It may also be used to reduce the dynamic range of a signal, creating a fuller sounding signal without increasing 
the loudness peaks, in which case it is functioning as a compressor.