ATTO Technology H308 Guia Do Utilizador
4
ExpressSAS RAID adapters
ATTO ExpressSAS RAID adapters are ideal for both
IT and digital video environments that require a high
level of protection and performance, supporting up to
64 end devices.
RAID improves data accessibility and reliability during
normal operations. A RAID group is a virtual,
independent single drive with data written to physical
drives according to a RAID algorithm.
The ATTO ExpressSAS RAID adapters support
JBOD, DVRAID™, RAID Level 0, 1, 4, 10, 5 and 6 and
advanced features such as read caching, Hot Spares,
automatic RAID group rebuilding and hot swap.
IT and digital video environments that require a high
level of protection and performance, supporting up to
64 end devices.
RAID improves data accessibility and reliability during
normal operations. A RAID group is a virtual,
independent single drive with data written to physical
drives according to a RAID algorithm.
The ATTO ExpressSAS RAID adapters support
JBOD, DVRAID™, RAID Level 0, 1, 4, 10, 5 and 6 and
advanced features such as read caching, Hot Spares,
automatic RAID group rebuilding and hot swap.
R348 technical specifications
• User-configurable as four external and four
internal ports or as eight internal ports
• Up to 3-Gb/sec per port performance
• Form factor conforms to PCI low-profile
• Form factor conforms to PCI low-profile
specification
• Length:
6.600”
• Height:
2.713”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 5 - 95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5 - 95% non-condensing
• Power: 12V @ 1.25A max; 3.3V@ 0.5A max
• Airflow: 150 lf/m minimum
• Operating humidity: 5 - 95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5 - 95% non-condensing
• Power: 12V @ 1.25A max; 3.3V@ 0.5A max
• Airflow: 150 lf/m minimum
R380 technical specifications
• Eight external ports
• Up to 3-Gb/sec per port performance
• Form factor conforms to PCI low-profile
• Up to 3-Gb/sec per port performance
• Form factor conforms to PCI low-profile
specification
• Length:
6.600”
• Height:
2.713”
• Operating temperature: 0-40 °C (32 °F-104 °F)
• Operating humidity: 5 - 95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5 - 95% non-condensing
• Power: 12V @ 1.25A max; 3.3V@ 0.5A max
• Airflow: 150 lf/m minimum
• Operating humidity: 5 - 95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5 - 95% non-condensing
• Power: 12V @ 1.25A max; 3.3V@ 0.5A max
• Airflow: 150 lf/m minimum
R30F technical specifications
• 1/2 height form factor
• Up to 3-Gb/sec per port performance
• Length:
• Up to 3-Gb/sec per port performance
• Length:
8.640”
• Height:
2.900”
• Operating temperature: 0-60 °C (32 °F-140 °F)
• Operating humidity: 5 - 95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5 - 95% non-condensing
• Power: 12V @ 1.7A max; 3.3V@0.9A max
• Airflow: 150 lf/m minimum
• Operating humidity: 5 - 95% non-condensing
• Storage temperature: -40-70 °C (-40 °F-157 °F)
• Storage humidity: 5 - 95% non-condensing
• Power: 12V @ 1.7A max; 3.3V@0.9A max
• Airflow: 150 lf/m minimum