Hoshizaki FH1-SSB(-HD) Guia Do Utilizador

Página de 23
9
• Electrical connections must be installed in accordance with applicable national, state, 
and local regulations.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• Cord-connected units should only be plugged into a 115 volt ±10%, 60 Hz circuit with a 
national and local electrical code approved, grounded wall receptacle. An independent 
circuit with its own circuit breaker (HACR type) or fuse (LP-CC type) should be 
provided. Refer to the nameplate for the proper electrical specifications.
• Hardwired units should only be wired into the proper conduit, with its own circuit 
breaker (HACR type) or fuse (LP-CC type). Electrical connection must be made in 
accordance with the instructions on the "WARNING" tag, provided with the pig tail 
leads in the junction box. Miswiring results in severe damage to the unit. Refer to the 
nameplate for the proper electrical specifications.
• Usually an electrical permit and services of a licensed electrician are required.
E. How to Open the Front Panel
1) Push the front panel up approximately 
1/ inch (1.3 cm) until it is disengaged 
from the locking collars and stops. See 
Fig. 6.
) Rotate the panel up and away from the 
face of the unit until it stops once more.
3) Pull the front panel forward until the hinge 
assembly is in the locked position. 
Pull Forward
Front Panel
Locking Collar
Rotate
Push Up
1
3
F. Door Reversal (except heated glass doors)
This unit is provided with a cabinet design which, after being delivered to the installation 
location, permits changing the door swing of doors from left to right or right to left. To 
change the door swing, special accessories are required. If installed improperly, the 
doors will not close and seal correctly. Contact your local Hoshizaki distributor, or the 
Hoshizaki Technical Support Department at 1-800-33-1940, if door reversal is desired.
Fig. 6