Display
Indication
Default
Refrigerator
Freezer
dEF
Next display after these is the defrost initiation 
temperature.
13°F 
(7°F for  
RH1-AAC-W)
NA
In1 
(Refrigerator 
Only)
13
Indicates that the setpoint for defrost initiation is 13°F.
dEF
Next display after these is the defrost termination temperature.
40°F
NA
End 
(Refrigerator 
Only)
40
Indicates that the setpoint for defrost termination is 40°F.
dEF
Next display after these is the number of hours between defrosts.
NA
Every 4 
hours
Int 
(Freezer Only)
4
Indicates that there will be one defrost every 4 hours. 
WARNING: This value should be adjusted only after consulting with 
the factory.
dEF
Next display after these is the maximum allowable time for a defrost. 
The freezer’s target is to terminate before this value is reached. This 
value is a safety.
NA
60 min.
dUr 
(Freezer Only)
60
Indicates that the maximum time for a defrost is 60 minutes. 
WARNING: This value should never be changed from the default.
dEF
Next display after these is the defrost termination temperature. The 
freezer’s target is to terminate at this value.
NA
100°F
HI 
(Freezer Only)
100
Indicates that the defrost termination temperature is 100°F.
SHo
Next display after these is the short cycle timer. The short cycle time 
is the minimum time the compressor must remain off in an off cycle 
or on in an on cycle.
.0 min.
.0 min.
CyC
Indicates that the short cycle timer is set to .0 minutes.
FAn
Next display after these is the re-initiation temperature of the 
evaporator fan after a defrost.
NA
70°F
HI 
(Freezer Only)
0
Indicates that the evaporator fan re-initiation temperature after a 
defrost is 70°F.
COI
Next display after these is the defrost sensor temperature.
NA
NA
SEn
0