Hoshizaki rh1-aac Manual Suplementar
19
Problem
Possible Cause
Remedy
[5] Cabinet temperature
too high.
a) Setpoint
1. Incorrect.
1. Correct setpoint. See
"II.B.1.b) Temperature
Setpoint."
Setpoint."
b) Door
1. Not sealing, or open for
long intervals.
1. Check for sealing, check for
door open at time of warm
cabinet temperature.
cabinet temperature.
c) Defrost
1. Not enough defrosts
occurring per day.
Operation in humid
conditions.
Operation in humid
conditions.
1. See "II.B.1.c) Defrost."
d) Refrigerant
1. Leak.
1. Repair leak and recharge.
e) Fan Motor
1. Defective.
1. Check and replace.
f) Air Filter
1. Clogged.
1. Clean.
g) Condenser
1. Dirty.
1. Clean.
h) Thermistor
1. Defective.
1. See "II.C. Thermistors."
Check and replace.
i) Control Module
1. Defective.
1. Replace.
[6] Cabinet temperature
display indicator does
not illuminate properly.
not illuminate properly.
a) Control Module
1. Defective.
1. Replace.
[7] Cabinet temperature
too low.
a) Thermistor
1. Defective.
1. See "II.C. Thermistors."
Check and replace.
b) Compressor Relay
1. Defective; contacts
welded.
1. Replace.
c) Control Module
1. Defective.
1. Replace.
[8] Evaporator does
not defrost completely.
a) Defrost Thermistor
1. Defective.
1. See "II.C. Thermistors."
Check and replace.
b) Defrost
1. Not enough defrosts
occurring per day.
Operation in humid
conditions.
Operation in humid
conditions.
1. See "II.B.1.c) Defrost."
c) Defrost Heaters
(freezers only)
1. Defective.
1. Replace heaters.
d) Safety Defrost
Thermostat
(freezers only)
(freezers only)
1. Defective, turning off
heaters prematurely, or
fused open.
fused open.
1. Replace safety defrost
thermostat.
[9] Defrost cycle
lasts too long.
a) Defrost Thermistor
1. Defective.
1. Replace.
b) Control Module.
1. Defective.
1. Replace.
c) Defrost
1. Not enough defrosts
occurring per day.
Operation in humid
conditions.
Operation in humid
conditions.
1. See "II.B.1.c) Defrost."
d) Defrost Heaters.
(freezers only)
1. Defective.
1. Replace heaters.
e) Safety Defrost
Thermostat
(freezers only)
(freezers only)
1. Defective, turning off
heaters prematurely, or
fused open.
fused open.
1. Replace safety defrost
thermostat.