Heat Shield
Support Clip (C)
Support Clip (B)
Support Clip (A)
Evaporator 
Bracket
F. Removal and Replacement of Heat Shield on FH2-SSB(-HD)
The heat shield was added to the evaporator assembly at auxiliary code M6. To replace 
the shield, follow the instructions below. 
1) Remove the original heat shield by lifting the evaporator up and sliding the heat shield 
out.
) Install the new heat shield in the rotocast drain pan.
3) Slide the clips onto the end plate on the evaporator. Install the two Support Clip (C) 
clips onto the hairpin end of the evaporator as shown in the illustration.
4) Install Support Clip (A) and Support Clip (B) onto the return bend end (same side as 
inlet and outlet tubes) as shown in the illustration.
Note: All clips are shown in the illustration in the correct orientation for installation. Slide 
the parts onto the evaporator brackets using the tabs on the support clips.
G. Removal and Replacement of Door Gasket
Remove old gasket by pulling it directly out of the vinyl gasket retainer. Thoroughly clean 
the gasket area with mild soap and water prior to installing the new gasket. The new 
gasket should be installed by assembling it at the corners first, then working toward the 
center at the top, bottom and sides. The arrow-shaped portion of the gasket should be 
firmly seated in the retainer groove for proper assembly. This can be checked by lifting 
the edge of the gasket and observing the engagement.
CAUTION 
In order to get a proper gasket fit, it is important not to stretch gasket material 
during assembly.