Checking the printer 
voltage
Make sure that the device has been set to the correct voltage (e.g. 
120 V in the USA, 230 V in Europe). To do this, check the type plate 
above the power inlet at the back of the printer. Contact your dealer 
if the setting is incorrect.
Never switch on the printer if the voltage setting is incorrect, 
since this may result in severe damage.
You can set the printer to the correct mains volt-
age yourself. To do this, cautiously place the print-
er on its back side.
Make sure that the fixing clips of the 
parallel connection are not bent.
Use a suitable object (e.g. a screwdriver, but nev-
er a pencil) to set the slide switch on the left at the 
bottom of the printer to the correct voltage.
STOP
pull
to
open
pull
to
open
STOP
120 V
Front side of printer
Back side of printer
230 V