Cma e-c-t Manual Do Utilizador

Página de 19
 
Title 
Rev 1.00A 
Installation & Operation 
 
 
Model 
EAH / EC Dishwasher 
01/26/04 
 
Page 4 
GETTING STARTED 
 
Introduction to EAH and EC 
 
CMA dishwashers have been used world wide for many years.  This manual has been written to help you, the 
operator, in your job.  Your job is one of the “most important” in this restaurant.  Why?  Your product, the dishes 
and glasses, is the first thing the customer notices when he sits down.  Clean, sparkling dishes and silverware will 
set the mood for the customer when he observes the table setting. 
 
Receiving and Installation 
 
The dishwasher is shipped from the factory bubble packed on a pallet.  The guidelines are listed in a step-by-step 
procedure for your reference. 
 
1.  Packaging 
Unwrap the machine and check for the following component parts: 
 Scrap accumulator complete with lid and scrap tray.  This is normally an integral part of the 
machine 
 
 Tube stiffeners.  Tube stiffeners must be used to prevent the feed tubes from curling inside the 
chemical pail and sucking air.  These are pre-installed to the chemical pump and attached to the 
back of the dishmachine.  The ends of the chemical tubing have been flared so that the tubing will 
not pull out of the stiffener.  Red is for detergent, white for sanitizer, and blue for rinse aid. 
 
2.  Plumbing 
The machine needs the following: 
 
 2” pipe for the drain outlet 
 
 ½” pipe for the incoming water 
 
 A flex hose or quick disconnect union.  The water inlet is at the top left corner of the dishwasher 
 
3.  Electrical 
The machine is 110 volt.  The master switch is at the top left side of the control box. 
 
4.  Chemical Feeder 
The peristaltic pumps are assembled and included within the machine. 
 
5.  Scrap Trap Accumulator 
The scrap trap accumulator is designed to perform two basic functions: 
 
 It allows a method to discharge all the heavy solids out of the machine with each wash and rinse 
cycle. 
 
 It provides capacity to drain the contents of one cycle regardless of the ability of the existing drain 
to accept the discharge rate. 
 
There is a drain connection sleeve (2”) on the bottom of the scrap accumulator (See drain connection 
instruction). 
 
CMA standard dishwashers operate on 110 volts.  Other voltage requirements are available on request.  
When installing the single rack units, either model EAH or EC, it is recommended that a clean 20 amp 
circuit be provided to the machine.