Printronix P5000LJ Manual De Referência

Página de 304
 34
Chapter
2
Configuring the PCL-II Emulation with Control Codes
UPC E
A fixed-length data string of 11 ASCII characters may be printed using the 
UPC E bar code. The string length must be 11 and may use any of the 
standard characters 0 through 9 (however, the data pattern must meet the 
format of UPC E bar codes; UPC E is a shortened version of very specific 
patterns printable with UPC A). If a non-valid character or string length is 
used, a blank non-readable bar code will be printed; non-valid characters are 
not substituted or deleted. For UPC E, a zero (0) is required in the first 
position of the bar code data (the number system character). The width of the 
printed bar code is not variable and is 0.81 inches.
EAN 8
A fixed-length data string of 7 ASCII characters may be printed using the 
EAN 8 bar code. The string length must be 7 and may use any of the standard 
characters 0 through 9. If a non-valid character or string length is used, a 
blank non-readable bar code will be printed; non-valid characters are not 
substituted or deleted. The width of the printed bar code is not variable and is 
1.25 inches.
EAN 13
A fixed-length data string of 12 ASCII characters may be printed using the 
EAN 13 bar code. The string length must be 12 and may use any of the 
standard characters 0 through 9. If a non-valid character or string length is 
used, a blank non-readable bar code will be printed; non-valid characters are 
not substituted or deleted. The width of the printed bar code is not variable 
and is 1.56 inches.
Royal Mail
A variable length data string may be printed using the “Royal Mail 4 State 
Customer Code”. The string may use any character from 0 through 9 and 
alpha characters A through Z. A complete bar code consists of a set of distinct 
bars and spaces for each character followed by a checksum character and 
enclosed by a unique start bar, stop bar and quiet zone. A second version of 
the Royal Mail barcode prints with no stop bar, start bar or checksum 
character.
The KIX format for Royal Mail does not include the start/stop code or the 
check digit, but will allow lowercase alpha characters a through z.
UCC/EAN 128
The UCC/EAN 128 bar code contains special characters which use unique 
codes to identify the leading and trailing end of the bar code. EAN/UCC 128 
supports a full ASCII character set and provides standard alphanumeric 
keyboard characters and control and special characters.
The EAN/UCC 128 data structure requires an Application Identifier (AI) at the 
beginning of barcode data. Each AI determines the format and length of the 
data which follows. Refer to Table 5 for more detail.