Equator ed510 Manual Suplementar

Página de 6
 
4
 
Dry Cycle  
Problem 
Possible Cause 
Repair Procedure 
1a. No power input. 
1a. Check that cord is plugged in, and 
circuit breaker or, if fuse is OK. Test 
unit power switch. 
1b. Door not closed. 
1b. Close door firmly, so that it latches 
tightly. 
1.  No tumble 
action. 
1c. Belt. 
1c. Check belt, adjust tension. 
2a. No Heat coming into the 
drum 
2a. Check the Fuse Link according to 
the instructions in Appendix A and 
replace if necessary. 
2b. Timer not advanced beyond 
the cool-down period. 
2b. Set dryer timer for times longer 
than 15 minutes. 
2c. Thermostats open. 
2c. Check for continuity, at room 
temperature. 
2d. Thermal fuse open. 
2d. Check for continuity. 
2e. Heating elements. 
2e. Check resistance: 25 ohms 
maximum open. 
2.  Clothes 
cold and damp 
at the end of 
the dry cycle. 
2f. Dryer timer. 
2f. Test for 115 vac between terminals 
B1 & 22 of Heat Timer 
3a. Blower impeller. 
3d. Remove and clean. Also check to 
see if condensing channel is clogged 
with lint. 
3.  Clothes hot 
and damp at 
the end of the 
dry cycle 
3b. * Blower housing to Tub 
Seals mismatched. 
 
 
 
 
3f. Disassemble blower housing from 
tub. Ensure that seals are positioned 
properly & reassemble.