Toshiba TDP-ET10 Guia Do Utilizador
![Toshiba](https://files.manualsbrain.com/attachments/acaaaa9cc6b763ccfc72ced2ae95d9c94b8b8632/common/fit/150/50/8adbcbcd45c75dc53932fc9caf6f2740daed52d836b76efbd0162ac2599f/brand_logo.png)
53
Others
Trouble indications
The indicator lights inform you of internal abnormalities.
LED indicators
State/Problems
No LED lit
No power
⇒ Problem with projector
• Unplug the power cord, and contact your dealer.
⇒ The lamp cover is not properly attached.
• Unplug the power cord, and reattach the lamp cover.
Red LED is fl ashing at ON/
STANDBY indicator (2Hz)
STANDBY indicator (2Hz)
Power went out during use
⇒ Internal overheating, or the outside temperature is too high.
• Place the projector so that the air intake and exhaust are not
blocked.
• Unplug the power cord and wait for a short while, then turn
the power back on.
❈ The icon will appear before the power goes out.
❈ The icon will appear before the power goes out.
❈ After approx. one minute of abnormal display, the projector
returns to the standby state waiting for internal cool down.
Red LED is fl ashing at ON/
STANDBY indicator (5Hz)
STANDBY indicator (5Hz)
Power went out during use
⇒ Problem with internal cooling fan.
• Unplug the power cord, and contact your dealer.
❈ The icon will appear before the power goes out.
❈ After approx. one minute of abnormal display, the projector
returns to the standby state waiting for internal cool down.
Red LED lit at ON/STAND-
BY indicator
BY indicator
Power went out during use, or won’t come on
⇒ Lamp temperature is high so that it is diffi cult to turn on,
the lifetime of the lamp has ended or the projector is
malfunctioning.
malfunctioning.
• Unplug the power cord and wait for a short while, then turn
the power back on.
• If a lamp burns out, replace it with a new one.
❈ After approx. one minute of abnormal display, the projector
returns to the standby state waiting for internal cool down.