Adtran 550 Guia Do Utilizador
Section 5 DLP-15
ATLAS 550 System Manual
350
© 2004 ADTRAN, Inc.
61200305L2-1B
1. Connect to the ATLAS 550 using either the ETHERNET, ADMIN, or CRAFT interfaces.
If you are not already connected to the unit’s
ADMIN
or
CRAFT
interface, either with a VT100
compatible terminal or with a PC running VT100 emulation software, use the procedure in DLP-2,
Logging in to the ATLAS 550, to connect to the
Logging in to the ATLAS 550, to connect to the
ADMIN
or
CRAFT
interface.
Alternatively, if the unit is part of a management cluster connected to the local network, you may use a
PC connected to the network to Telnet into the unit. To connect to the
PC connected to the network to Telnet into the unit. To connect to the
ETHERNET
interface, use the
procedures in DLP-3, Setting IP Parameters for the ATLAS 550, and in DLP-4, Verifying
Communications Over an IP LAN.
Communications Over an IP LAN.
2. Log in to the unit using the read-write password (see DLP-2, Logging in to the ATLAS 550, for details).
1. Go to the S
YSTEM
C
ONFIG
menu and press the right-arrow key to access the right-pane menus. Select
the A
LARM
R
ELAY
T
HRESHOLD
menu and choose the appropriate threshold level. The A
LARM
R
ELAY
will set for this threshold and all other alarms of greater importance. Refer to Section 7, System Event
Logging of this user manual for a listing of all alarms and levels of importance.
Logging of this user manual for a listing of all alarms and levels of importance.
1. Go to the S
YSTEM
C
ONFIG
menu and press the right-arrow key to access the right-pane menus. Then,
select the E
VENT
L
OGGING
menu and press <Enter>. Once in the E
VENT
L
OGGING
menu, press the
right-arrow key to access the right-pane menus.
2. From the E
VENT
L
OGGING
menu, select the E
XTERNAL
I
NPUT
menu and set it to the same value as the
A
LARM
R
ELAY
T
HRESHOLD
. Any event on the A
LARM
M
ONITOR
will now be logged in the E
VENT
L
OG
and
set the A
LARM
R
ELAY
.
1. Go to the S
YSTEM
C
ONFIG
menu and press the right-arrow key to access the right-pane menus. Then,
select the A
LARM
R
ELAY
R
ESET
field and press <Enter>.
Perform the following steps below in the order listed:
Configuring the Alarm Relay
Setting the threshold to
N
ORMAL
will not set the
A
LARM
R
ELAY
for
N
ORMAL
events. No
N
ORMAL
events set the
A
LARM
R
ELAY
.
(Optional) Configuring the Alarm Monitor for External Alarms
Clearing the Alarm Relay Remotely
Clear the
A
LARM
R
ELAY
locally by pressing the
ACO
switch on the front panel.