Total Access 600 Series System Manual
Section 4  User Interface Guide
61200624L1-1B
© 2004 ADTRAN, Inc.
171
FXS Interface Setup Instructions 
Step
Action
1
From the main menu, select I
NTERFACES
.
2
Highlight the C
ONFIG
 menu for the FXS interface and press <E
NTER
>.
3
Right arrow to select M
ODE
 and choose L
OOP
 S
TART
G
ROUND
 S
TART
T
ANDEM
 (E&M)TR08 S
INGLE
TR08 UVG, or DPO.
This mode should be set based on the network configuration and the 
operation of each FXS port. All FXS ports are independent and do not 
need to have the same mode.
4
Set the T
X
 (dB) or transmit direction level for each port. The default 
value is recommended.
5
Set the R
X
 (dB) or received direction level for each port. The default 
value is recommended.
6
Set the S
VC
 M
ODE
 to I
N
 S
ERVICE
 to activate the port. 
7
Set the L
INE
 Z (line impedance) of each port based on the size of the 
network. The default value is recommended.
8
Set the M
SG
 I
ND
 to D
ISABLE
 or E
NABLE
. When set to E
NABLE
, talk path is 
always open, even in on-hook conditions, in order for FXS message 
tones to pass through. Disabling this feature will allow higher on-hook 
voltage but will not allow on-hook messaging other than caller ID.
9
Configure the on-hook battery voltage using the B
ATT
 M
ODE
 field. For 
most IAD installs, the FXS loop is short with 6 to 7 V present on tip / ring. 
To reduce power dissipated during off-hook conditions, the battery is 
lowered for short loop lengths. When set to A
UTO
 S
WITCH
, the IAD uses 
a higher on-hook battery voltage (48-52 V). When off-hook, it 
automatically switches to low battery (24-26 V) to minimize power 
dissipation. When set to L
OW
 B
ATTERY
 mode, the higher battery is not 
used and the voltage is a constant 26 V even while on-hook. The tip/ring 
voltage is reduced to 26 V when using the L
OW
 B
ATTERY
 mode.
10
Specify the interval of battery removal during a forward disconnect state
 
using the F
WD
 D
ISC
 T
IMER
 field. Choices are F
OLLOW
 S
WITCH
 (default), 
500
MS
750
MS
1000
MS
, and 2000
MS
. When using ATM mode, there is 
an additional choice of I
GNORE
 S
WITCH
. If the timer is set to F
OLLOW
 
S
WITCH
, the
 
Total Access 6XX will follow the switch at all times; this is normal 
operation. If a time period has been selected, the Total Access 6XX will 
remove battery for the specified time period OR as long as the switch 
requests battery removal, whichever is longer. For example, if the timer 
expires but the switch continues to request battery removal, the Total 
Access 6XX will follow the switch and continue to remove battery. For 
ATM mode, if the timer is set to I
GNORE
 S
WITCH
, the IAD will never 
remove battery.