Adtran 544r Manual Técnico

Página de 162
Section 5 DLP-12 
Total Access 544R System Manual
 136
© 2003 ADTRAN, Inc.
61200704L2-1B
1. Connect to the unit using the RJ-45 CRAFT interface.
If you are not already connected to the unit’s 
CRAFT
 interface (either with a 
VT100 compatible terminal or with a PC running VT100 emulation software), follow the procedure in 
DLP-1, Connecting the Terminal or PC to the CRAFT Port. Connecting to the 
CRAFT
 interface limits 
the config transfer procedure to XMODEM Only.
2. Log in to the unit. (See DLP-2, Logging in to the System, for details.)
3. Go to the S
YSTEM
 U
TILITY
 menu and select C
ONFIGURATION
 T
RANSFER
 menu; press <Enter>
4. Set the T
RANSFER
 M
ETHOD
 menu to XMODEM.
5. Select L
OAD
 
AND
 U
SE
 C
ONFIG
 to start the transfer. Enter Y to confirm the transfer and prepare the unit 
for the transfer download. 
When the unit is ready to receive the XMODEM configuration file, the menu screen will clear and 
display XMODEM/CRC: Transmit CONFIG file now... If this does not appear, please review the 
steps above for possible configuration errors.
6. From the terminal emulation software, begin the XMODEM transfer by using the appropriate command 
sequence. For Windows HyperTerminal, select T
RANSFER
 > S
END
 F
ILE
. Enter the filename (including 
path) and select XMODEM as the T
RANSFER
 M
ETHOD
. Configuration files should have a .cfg extension.
If necessary, refer to the terminal emulation software documentation for help. 
Because XMODEM data is being transferred in-band through the menu interface, the VT100 menus of 
the unit will be inoperable from the 
CRAFT
 interface. You can cancel the update at any time within the 
terminal emulation software. (Please consult the documentation provided by the terminal emulation 
software to determine how to do this.) 
7. After the config transfer is complete, the C
ONFIG
 T
RANSFER
 menu will be displayed.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with 
the tasks indicated there.
Perform Steps Below in the Order Listed
The following message is displayed: “Warning: WAN link may be reset after transfer 
complete!”