USER’S GUIDE
338      CyberSWITCH
V
ERIFYING
 
A
 D
EDICATED
 C
ONNECTION
To verify a dedicated connection to the CyberSWITCH, the WAN lines that are connected to the 
system must be available for use, and the routing option must be properly initialized.
To verify that you have a dedicated connection:
1.
View the system messages by entering the following console command:
dr
 
<return>
2.
Look for the following system message among the displayed messages:
Layer 1 sync not seen - Slot=<slot #> Port=<port #> Ces=<communication 
endpoint suffix>
If the above message appears, a physical problem has been detected on the indicated line. 
Check for a proper connection to the CyberSWITCH and to the NT1 or CIU. If the NT1 or CIU 
appears to be functioning properly, call your carrier service and report the problem.
If the above message does not appear in the displayed messages, proceed to the next step.
3.
Look for the following system message among the displayed messages:
Dedicated connection to device <device name> up: Slot=<slot#>, 
Port=<port #>
If the above message is displayed, the dedicated connection is functioning. 
If the following message appears, the dedicated connection is not functioning.
Dedicated connection down: Slot=<slot#>, Port=<port #>
Refer to 
 in the Problem Diagnosis chapter. Because all remote devices 
that use dedicated connections are PPP devices, follow the described set-up procedure, then 
skip to the step specific for 
.
V
ERIFYING
 
A
 F
RAME
 R
ELAY
 C
ONNECTION
To verify a frame relay connection to the CyberSWITCH, the WAN lines that are connected to the 
System must be available for use, and the routing option must be properly initialized. To verify a 
connection, the a remote device must have a connection established.
Enter the 
frame relay stats 
command at the administration console. If the statistics display 
appears, the frame relay subsystem should be operational. If the following message is displayed, 
frame relay is not configured:
No Frame Relay Accesses configured
Enter the 
cs 
command at the administration console. The device name for the associated PVC 
should appear in the list of connected sites.
If you receive the above message, or if the device name for the associated PVC does not appear in 
the list of connected sites, then refer t
 of the Problem Diagnosis chapter.