Enterasys csx150 Guia Do Utilizador

Página de 620
USER’S GUIDE
346      CyberSWITCH
V
ERIFYING
 IP R
OUTING
 O
VER
 
A
 WAN R
EMOTE
 LAN I
NTERFACE
To verify that IP routing is properly operational over a WAN Remote LAN interface, a remote IP 
Host must be operational and connected to the remote LAN. The remote bridge device must be 
operational and available to initiate connections. Also, a local IP host must be connected to the local 
LAN port on the CyberSWITCH.
Below is an example of a configuration used to verify IP routing over a WAN Remote LAN 
interface. It uses IP addresses specific to the example. Substitute the IP addresses of your network 
when you perform the IP routing verification steps. It also uses the “ping” command. The “ping” 
command sends a packet to a specified host, waits for a response, and reports success or failure. 
Substitute the equivalent command on your IP host.
The steps to verify the operation of IP routing over a WAN Remote LAN interface are:
1.
Determine if a remote IP host can access the WAN Remote LAN interface of the CyberSWITCH 
over the WAN connection. On the remote IP host type:
ping 192.100.1.1 
<return>
If the remote IP host successfully pings to the CyberSWITCH, then continue with the next step.
If the remote IP host CANNOT ping to the CyberSWITCH, refer to 
 of the Problem Diagnosis chapter.
2.
Determine if a remote IP host can access the LAN interface of the CyberSWITCH over the WAN 
connection. On the remote IP host type:
ping 100.0.0.1 
<return>
If the remote IP host successfully pings to the CyberSWITCH, then continue with the next step.
If the remote IP host CANNOT ping to the CyberSWITCH, refer to
 of the Problem Diagnosis chapter.
3.
Determine if a remote IP host can access the local IP host through the CyberSWITCH over the 
WAN connection. On the remote IP host type:
ping 100.0.0.2 
<return>
100.0.0.1
100.0.0.0
Host A
100.0.0.2
Host B
192.100.1.3
ISDN
Bridge
192.100.1.1
CSX150