Small Office Remote Access Switch      393
P
ROBLEM
 D
IAGNOSIS
Call Detail Recording
If there are no problems with actions 1 and 2, proceed to action 3. 
3.
Check for the following system messages:
In - proceeding <#,#>
In - disconnect <#,#> - <disconnect cause>
If the system reports these messages, then the network disconnected the call attempt. For the 
disconnect cause meaning, refer to the 
 table. If help is necessary to resolve the 
reported disconnect cause, write down the “disconnect cause” and call your phone company 
(carrier) to report the problem.
C
ALL
 D
ETAIL
 R
ECORDING
Problem:
The
 cdr verify 
command fails for an off-node server.
Action:
1.
Ping the syslog server to check the IP route from the CyberSWITCH to the server. (Note that an 
IP route to the server must be established.) If RIP is needed to establish the route, the route may 
not be available until the CyberSWITCH has been running for a minute or two.)
2.
Using the 
dr
 command, check the CyberSWITCH Report log for error messages.
3.
Check that the syslogd daemon is running on the syslog server. This can be done with your 
UNIX system’s process status (ps) command. This command should result in a display of the 
syslogd process. If none is displayed, syslogd is not running.
4.
Syslogd can be run in debug mode with the “-d” option. See your UNIX system documentation 
for more information on your syslogd daemon process.
5.
If syslogd is running but does not receive any log messages, make sure CDR is configured for 
the UDP port that syslogd is using. The typical port is 514, but some versions of syslogd may 
use a different port.
6.
Check that the priority value that you assigned in the CFGEDIT Call Detail Recording menu 
(default of 38) matches the priority setting on your syslog server (default of auth.info).
C
OMPRESSION
Problem:
Compression is not established for a device for which it is expected.
Action:
1.
Issue the 
cmp stats
 console command then issue the 
dr
 console command to check the 
message report log. A message will inform you if the compression failed due to memory 
constraints. 
2.
Verify that the CyberSWITCH has compression enabled. This is done through selecting 
“Compression Options” from CFGEDIT’s Systems Options menu.