Diagnostic error codes
Refer to the following diagnostic error codes when using the diagnostic tests. See “Running tests” on page
34 
for the specific type for information about the diagnostic programs.
In the following index, X can represent any number.
Diagnostic Error Code
FRU/Action
000-000-XXX BIOS Test Passed
No action
000-002-XXX BIOS Timeout
1. Flash the system. See “Updating (flashing) the
2. System board
000-024-XXX BIOS Addressing test failure
1. Flash the system. See “Updating (flashing) the
2. System board
000-025-XXX BIOS Checksum Value error
1. Flash the system. See “Updating (flashing) the
2. System board
000-026-XXX FLASH data error
1. Flash the system. See “Updating (flashing) the
2. System board
000-027-XXX BIOS Configuration/Setup error
1. Run the Setup Utility program.
2. Flash the system. See “Updating (flashing) the
3. System board
000-034-XXX BIOS Buffer Allocation failure
1. Reboot the system.
2. Flash the system. See “Updating (flashing) the
3. Run memory test
4. System board
000-035-XXX BIOS Reset Condition detected
1. Flash the system. See “Updating (flashing) the
2. System board
000-036-XXX BIOS Register error
1. Flash the system. See “Updating (flashing) the
2. System board
000-038-XXX BIOS Extension failure
1. Flash the system. See “Updating (flashing) the
2. Adapter card
3. System board
000-039-XXX BIOS DMI data error
1. Flash the system. See “Updating (flashing) the
2. System board
000-195-XXX BIOS Test aborted by user
Information only Restart the test, if necessary
000-196-XXX BIOS test halt, error threshold exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
44
ThinkStation Hardware Maintenance Manual