ATTO Technology diamond array v Manual Do Utilizador

Página de 117
55
 
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
 5.3  RAID Level 1
The Diamond Storage Array can be set up into RAID Level 1 (mirrored) groups, with or without hot 
spare sleds, to provide greater reliability by simultaneously writing data to two sleds. Each sled 
partnered through QuickRAID1, a CLI command, has the same data as its partner. 
CAUTION
CAUTION
Selecting RAID configuration causes all 
previous drive data on the Diamond 
Storage Array to be erased. Make sure all of 
your information is backed up before 
setting up RAID groups.
The configuration of RAID Level 1 performs the 
same operations on two partnered sleds at the 
same time, providing an automatic backup of 
data. The operating system sees the two sleds as 
one Virtual Drive with its own LUN (Logical Unit 
Number). 
The QuickRAID1 command allows the 
Diamond Storage Array to be set into mirrored 
drives. The command first spans two drives on a 
sled together, then partners two sleds to be a 
RAID Level 1 group designated by a LUN 
(logical unit number).
When you initially set up RAID groups using the 
QuickRAID command, groups are synchronized 
automatically because there is no pre-existing 
data on the drives. However, drives may display 
as “degraded, and you need to set all LUNs to OK 
status. Refer to 
Note
Because the ExpressNAV pages take you 
through this process easily, the following 
instructions are based on the CLI commands. 
Use these instructions as a guide in 
ExpressNAV.
To set up RAID Level 1 groups
1
Connect to Diamond Storage Array services via 
the RS-232 port or the optional Ethernet 
management services card (refer to 
Accessing 
the Array 
on page 17). You should now be in 
Command Line Interface.
2
Continue with the CLI or access the RAID page 
of the ExpressNAV interface (refer to 
ATTO 
ExpressNAV: Browser-based Interface 
on page 25). 
3
QuickRAID1 has no options: the command sets 
up each sled and its mirror image. Type 
set 
QuickRAID1.
 
4
Information displays on the screen while the 
array updates NVRAM ending with a Ready*.
5
Type SaveConfiguration.
6
Type FirmwareRestart to reboot the array.
7
Reboot the host computer connected via Fibre 
Channel or SCSI to the array. 
8
The array is now configured. To verify the 
configuration, type DriveInfo. If any sleds are 
missing, the sled slots are reported as offline.
In a fully populated array, your operating system 
displays you have six drives. 
Note
In a less than fully populated array, if both 
partners of a LUN are missing, the LUN does 
not exist. If only one partner is missing, the 
LUN does exist, but it is degraded 
(unprotected). See Exhibit 5.3-1 t
o determine 
which LUNs would be affected.
To set up RAID Level 1 with Hot Spare sleds
1
Connect to Diamond Storage Array services 
(refer to 
Accessing the Array 
on page 17) and use 
the CLI or enter ATTO ExpressNAV browser 
interface Advanced CLI configuration page. 
2
Type set QuickRAID 1 2
3
Type SaveConfiguration Restart
The Diamond is configured into one RAID Level 1 
group with two Hot Spare sleds.
To remove RAID groups 
1
Connect to Diamond Storage Array services via 
the RS-232 port or the optional Ethernet 
management services card (refer to 
Accessing 
the Array 
on page 17). You should now be in 
CLI.