ATTO Technology diamond array v Manual Do Utilizador

Página de 117
79
 Diamond Storage Array
These error messages should be reported to 
technical personnel to assist in debugging the 
problem. 
The blink codes are also saved internally by the 
array to NVRAM (Non Volatile Random Access 
Memory) and are displayed at power up if the 
power to the array is recycled. 
Disk Drive Activity and Disk Fault LEDs 
Each 
dual disk drive sled assembly contains two green 
activity LEDs and an amber Disk Fault LED. 
Once the system has successfully powered up and 
passed POST, the green activity LEDs are full on 
and the Disk Fault LED off. 
The Drive 1 and Drive 2 activity LEDs stays full 
on when the system is operational and no disk 
drive activity is present. As the disk drives are 
accessed, the green LEDs flashes. If the disk 
drives are heavily accessed the green activity 
LEDs appears to flash at a high rate or may even 
appear to be completely turned off. 
The amber Disk Fault LED is off under normal 
operation. If either of the disk drives on a dual 
disk drive assembly reports a disk error of any 
kind, the amber Disk Fault LED lights. The Disk 
Fault LED can be activated by minor issues such 
as a disk drive writing to a bad sector (which is 
usually corrected by the disk drive the next time it 
writes) or major issues such as a head crash or 
complete drive failure. 
When the Disk Fault LED is turned on, the system 
issues a detailed message via the CLI. These 
messages are not written permanently to the error 
log file but should be recorded to help assess the 
disk problem. 
If the disk drive error is a non fatal error and the 
drive is still functional, the array continues to read 
and write data to the disk drive but the Disk Fault 
LED remains on. If you repeat a drive command 
or action and it completes successfully, the Disk 
Fault LED may have been set by an anomaly in 
the disk drive. You can clear the Disk Fault LED 
by either power cycling the array or issuing the 
SledFaultLED command in CLI as per 
If you repeat a disk command or action and the 
Disk Fault LED remains on, the disk error may be 
serious. You should write down the error message 
issued by the CLI and contact technical support 
via the means easiest for you for assistance (refer 
to 
on page xvi). If you choose to replace 
the suspected faulty dual disk drive sled assembly, 
follow the appropriate procedures.