ATTO Technology diamond array s Manual Do Utilizador

Página de 105
15
 
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
 4.0  Determining Drive and Sled Designations
The Diamond Storage Array has been designed with 12 sleds, each holding two drives. The easiest way 
to configure a array is to use all the drives on all the sleds. The firmware uses a numbering system to 
determine which drives and sleds it is affecting. 
We recommend that all sled slots are filled 
contiguously, starting with the first slot next to the 
management card. 
When configuring a Diamond Array with fewer 
than 12 drive sleds, you must consider several 
factors: RAID level, number of physical 
drives/sleds and the end configuration you are 
trying to achieve. Review the information about 
each configuration to determine how each 
configuration would be affected by using fewer 
sleds.
Numbering conventions
The Diamond Storage Array with firmware 
version 3.1 and newer uses a unique numbering 
convention to orient its drives and sleds to the 
controlling firmware. Older versions do not use 
this convention. (Refer to 
page 77 for information about updating the array 
firmware.)
Physical 
refers to the physical drives in the array, 
the hardware that actually exists in a physical 
sense.
Logical (or virtual)  
refers to what the host 
operating system recognizes as an entity. Two 
physical drives may be seen as one logical drive 
by the operating system.
Logical disks do not always map one-to-one with 
physical disks. 
In RAID configurations, for 
example, several physical disk drives (or portions 
of several physical drives) are grouped into a
logical disk or Logical Unit (LUN). Each LUN is
broken into logical blocks of 512 bytes each, 
numbered 0 through n (the Logical Block Number 
or LBN). A 100 GB LUN has approximately 
200,000,000 logical blocks. 
Physical numbering 
The Diamond RAID Storage Array contains 
•  Up to 24 physical disk drives 
•  Two drives mounted on 12 physical drive sleds 
•  Sleds are numbered 1-12, starting at the top 
(floor units) or the left (rackmount units). 
•  Each sled is connected to its own internal ATA 
bus with two disk drives, numbered 1 and 2. 
•  Two green LEDs, labeled Drive 1 and Drive 2, 
indicate activity for the two drives. They remain 
solidly lighted when there is no activity.
Logical numbering
Logical numbering depends on 
the RAID configuration of the 
storage array. S Class firmware 
includes RAID Level 0, RAID 
Level 1, RAID Level 10 and 
RAID Level 5 capability. A 
variety of configurations may 
be selected using the 
QuickRAID0 command. The 
default configuration is 
QuickRAID0 0 or JBOD (Just 
a Bunch of Disks). 
  1             2           3
    4
    5             6            7             8              9            10           11         12
Rack Mount Drive Sleds
Management Card
Disk 2
LUN 13
Disk 2
LUN 14
Disk 2
LUN 15
LUN 16
LUN 17
Disk 2
LUN 18
LUN 19
LUN 20
Disk 2
LUN 21
Disk 2
LUN 22
Disk 2
LUN 23
Disk 2
LUN 24
Disk 1
LUN 12
Disk 1
LUN 11
Disk 1
LUN 10
Disk 1
LUN 9
Disk 1
LUN 8
Disk 1
LUN 6
Disk 1
LUN 4
Disk 1
LUN 3
Disk 1
LUN 2
Disk 1
LUN 1
Disk 1
LUN 5
Disk 1
LUN 7
Disk 2
LUN 19
Disk 2
LUN 20
Disk 2
LUN 17
Disk 2
LUN 16
  
1  
    
  
    
 2
    
    
  3
    
4
    
5
  
    
    
  
6
    
     
  
7
   
  
    
   8
   
  
    
    
 9 
  
    
    
 10
   
  
    
  1
1  
   
  
  12
Fl
oor
 M
ode
l  D
riv
S
le
ds
Drive 2
LUN 13
Drive 2
LUN 14
Drive 2
LUN 15
LU
N
 17
Drive 2
LUN 18
L
UN 1
9
LU
N
 2
0
Drive 2
LUN 21
Drive 2
LUN 22
Drive 2
LUN 23
Drive 2
LUN 24
Drive 1
LUN 12
Drive 1
LUN 11
Drive 1
LUN 10
Drive 1
LUN 9
Drive 1
LUN 8
Drive 1
LUN 6
Drive 1
LUN 4
Drive 1
LUN 3
Drive 1
LUN 2
Drive 1
LUN 1
Drive 1
LUN 5
Drive 1
LUN 7
Drive 2
LUN 19
Drive 2
LUN 20
Drive 2
LUN 17
Drive 2
LUN 16
Management card
Drive 1
LUN 6
Drive 1
LUN 12