Zhone 2000 Guia Do Utilizador
R e p o r t s
173
Display G7070 ADSL Statistics (20xx)
This report displays ADSL statistics.
Rx Cells Discarded
No. of received packets discarded due to:
- Unknown VPI/VCI numbers
- Bad Cell headers
- Size of cells received is larger than PDU size
- other reasons as required.
- Unknown VPI/VCI numbers
- Bad Cell headers
- Size of cells received is larger than PDU size
- other reasons as required.
Cells Tx
No. of valid ATM cell sent.
OAM Tx
No. of cells transmitted with CLPI (Cell Loss Priority
Indication) bit is on.
Indication) bit is on.
CLPI Tx
No. of OAM (Operation And Maintenance) cells
transmitted.
transmitted.
EFCI Tx
No. of cells transmitted with EFCI (Explicit Forward
Congestion Indication) bit is on.
Congestion Indication) bit is on.
RM Tx
No. of RM (Resource Management) cells transmitted.
Rx HEC Errors
No. of cells receives with HEC errors in the header.
Lost Cell Delineation (OCD) No. of times cell delineation was lost.
Time in OCD
Amount of time in OCD condition
ATM Sync
Current ATM Synchronization status—Established or
Lost.
Lost.
Parameter
Description
Operational Seconds
Total kernel time (in seconds) link was operational.
Downstream SNR Margin
Current rate of downstream signal-to-noise ratio
margin.
margin.
Downstream Attenuation
Current rate of downstream attenuation.
Upstream Attenuation
Current rate of upstream attenuation.
Near-End FEC
Count of near-end forward error correction.
Near-End CRC
Count of the near-end interleaved symbols with cyclic
redundancy check errors.
redundancy check errors.
Near-End SEF
Count of near-end severely errored frames.
Near-End LOS
Count of near-end loss of signal frames.
Far-End FEC
Count of far-end forward error correction.
Far-End CRC
Count of far-end cyclic redundancy check.
Far-End SEF
Count of far-end severely errored frames.
Far-End LOS
Count of far-end loss of signal frames.
Field