Zhone 7995 Instrução De Instalação

Página de 32
16
Send (AIS) on Network Failure
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies the action taken on the signal transmitted to the G.703 when a valid signal 
cannot be recovered from the network interface (LOS or OOF).
Primary Clock Source
Possible Settings: G.703, Internal
Default Setting: Internal
Specifies from where the unit will derive its timing.
Table 5. System Options  (1 of 2)
DSL Mode
Possible Settings: STU-CSTU-R
Default Setting: STU-R
Controls whether the unit is configured as a SHDSL Transceiver Unit – Central Site 
(STU-C) or a SHDSL Transceiver Unit – Remote Terminal Site (STU-R).
NOTE: Changing this option will reset the unit.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is 
remotely managed so that control can be regained after a test is accidentally 
executed.
Test Duration (min)
Possible Settings: 1 – 120
Default Setting: 10
Number of minutes for a test to be active before automatically ending. 
G.703 Line Termination
(Model 7996)
Possible Settings: 75 ohms, 120 ohms
Default Setting: 120 ohms
Sets the line impedance for the unit.
Table 4. G.703 Interface Options – Model 7996 (2 of 2)