Zhone 7995 Instrução De Instalação

Página de 32
30
 Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or 
included in the manual.
2. Input power to this product must be provided by one of the following: (1) a UL 
Listed/CSA Certified power source with a Class 2 or Limited Power Source (LPS) 
output for use in North America; or (2) a 24 or –48 VDC National Electric Code 
(NEC) ANSI/NFPA 70/Canadian Electric Code (CEC) Class 2 circuit installed in 
accordance with articles 110-16, 110-17, and 110-18 of the NEC, and articles 
2-308, 2-310, 2-312, 2-314, 2-200, and 2-202 of the CEC, or (3) a Safety Extra Low 
Voltage (SELV) power source with a maximum available output of less than 240 VA, 
certified for use in the country of installation.
3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable 
operation of the product and to protect it from overheating, these slots and 
openings must not be blocked or covered.
4. Do not allow anything to rest on the power cord and do not locate the product where 
persons will walk on the power cord.
5. Do not attempt to install or service this product yourself, as opening or removing 
covers may expose you to dangerous high voltage points or other risks. Refer all 
installation and servicing to qualified service personnel.
6. General purpose cables are provided with this product. Special cables, which may 
be required by the regulatory inspection authority for the installation site, are the 
responsibility of the customer.
7. When installed in the final configuration, the product must comply with the 
applicable Safety Standards and regulatory requirements of the country in which it 
is installed. If necessary, consult with the appropriate regulatory agencies and 
inspection authorities to ensure compliance.
8. A rare phenomenon can create a voltage potential between the earth grounds of 
two or more buildings. If products installed in separate buildings are 
interconnected, the voltage potential may cause a hazardous condition. Consult a 
qualified electrical consultant to determine whether or not this phenomenon exists 
and, if necessary, implement corrective action prior to interconnecting the products.
9. In addition, if the equipment is to be used with telecommunications circuits, take the 
following precautions:
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically 
designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone line 
has been disconnected at the network interface.
Use caution when installing or modifying telephone lines.
Avoid using a telephone (other than a cordless type) during an electrical storm. 
There may be a remote risk of electric shock from lightning.
Do not use the telephone to report a gas leak in the vicinity of the leak.
!