Zhone 7995 Guia Do Utilizador

Página de 154
7. Testing
7990-A2-GB20-00
May 2002
7-11
Send Remote Data Channel Loopback
The local termination unit can send an Up or Down sequence to request the start 
or stop of a Data Channel Loopback (DCLB) on a remote unit. 
Procedure
 
To send a Remote DCLB:
1. Position the cursor at the Up or Down selection next to Send Remote DCLB 
on the SYNC Data Port Tests screen.
2. Press the spacebar to select the desired code (Up or Down).
3. Position the cursor at the Start command next to Send Remote DCLB on the 
SYNC Data Port Tests screen.
4. Press Enter.
The Status field is changed to Sending. The Up or Down sequence 
transmission stops automatically after 10 seconds. You cannot stop the 
sequence manually. 
02-15935-02
Port
Interface
Framer
EIA-530
Port
CAP
All Ones
Port
Interface
Framer
CAP
Local
Remote
DSL