Basic Setting 
6-3 
Table 6-1 System Info 
LABEL 
DESCRIPTION 
Ethernet Address 
This field refers to the Ethernet MAC (Media Access Control) address of the switch. 
 
Hardware Monitor 
Temperature Unit  
The switch has temperature sensors that are capable of detecting and reporting if the 
temperature rises above the threshold. You may choose the temperature unit (Centigrade 
or Fahrenheit) in this field.  
Temperature  MACCPUPHY1PHY2PHY3 and ENV refer to the location of the temperature sensors 
on the switch printed circuit board. 
Current  This field displays the current temperature measured at this sensor. 
MAX  This field displays the maximum temperature measured at this sensor. 
MIN  This field displays the minimum temperature measured at this sensor. 
Threshold  This field displays the upper temperature limit at this sensor. 
Status  This field displays Normal for temperatures below the threshold and Error for those above. 
Fan speed (RPM)  
A properly functioning fan is an essential component (along with a sufficiently ventilated, 
cool operating environment) in order for the device to stay within the temperature 
threshold. Each fan has a sensor that is capable of detecting and reporting if the fan speed 
falls below the threshold shown.  
Current  This field displays this fan's current speed in Revolutions Per Minute (RPM). 
MAX  This field displays this fan's maximum speed measured in Revolutions Per Minute (RPM). 
MIN  This field displays this fan's minimum speed measured in Revolutions Per Minute (RPM). 
"<41" is displayed for speeds too small to measure (under 2000 RPM). 
Threshold  This field displays the minimum speed at which a normal fan should work. 
Status  Normal indicates that this fan is functioning above the minimum speed. Error indicates 
that this fan is functioning below the minimum speed.  
Voltage (V)  
The power supply for each voltage has a sensor that is capable of detecting and reporting 
if the voltage falls out of the tolerance range.  
Current  This is the current voltage reading. 
MAX  This field displays the maximum voltage measured at this point. 
MIN  This field displays the minimum voltage measured at this point. 
Threshold  This field displays the minimum voltage percentage at which the switch should work. 
Status  Normal indicates that the voltage is within an acceptable operating range at this point; 
otherwise  Error is displayed. 
Poll Interval(s) 
 
The text box displays how often (in seconds) this screen refreshes. You may change the 
refresh interval by typing a new number in the text box and then clicking Set Interval.